Troubleshooting – Desa Tech CHDV34PA User Manual

Page 28

Advertising
background image

28

105983

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

CHDV34NA, PA

TROUBLESHOOTING

Note:

All troubleshooting items are listed in

order of operation.

WARNING: Turn off heater

and let cool before servicing. Only
a qualified service person should
service and repair heater.

CAUTION: Never use a wire,

needle, or similar object to clean
pilot. This can damage pilot unit.

POSSIBLE CAUSE

1. Ignitor electrode not connected to igni-

tor cable

2. Ignitor cable pinched or wet

3. Piezo ignitor nut is loose

4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong

1. Gas supply turned off or manual shutoff

valve closed

2. Gas control knob not in PILOT position
3. Gas control knob not pressed in while

in PILOT position

4. Air in gas lines when installed

5. Depleted gas supply (propane/LP models

only)

6. Pilot is clogged

7. Gas regulator setting is not correct

1. Gas control knob not fully pressed in
2. Gas control knob not pressed in long

enough

3. Manual shutoff valve not fully open
4. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged pilot

5. Thermocouple connection loose at con-

trol valve

6. Thermocouple damaged
7. Control valve damaged

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

3. Tighten nut holding piezo ignitor. Nut

is located behind the mounting bracket

4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace pilot assembly
7. Replace pilot assembly

1. Turn on gas supply or open manual

shutoff valve

2. Turn gas control knob to PILOT position
3. Press in gas control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is re-
moved

5. Contact local propane/LP gas company

6. Clean pilot (see Cleaning and Mainte-

nance, page 27) or replace pilot assembly

7. Replace gas control

1. Press in gas control knob fully
2. After pilot lights, keep gas control knob

pressed in 30 seconds

3. Fully open manual shutoff valve
4. A) Contact local gas company

B) Clean pilot (see Cleaning and
Maintenance
, page 27) or replace pi-
lot assembly

5. Hand tighten until snug, then tighten

1/4 turn more

6. Replace thermocouple
7. Replace control valve

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at pilot

When ignitor button is pressed, there is
spark at pilot but no ignition

Pilot lights but flame goes out when control
knob is released

www.desatech.com

Note:

For additional help, visit DESA

International’s technical service web
site at

www.desatech.com

.