Utility connections electric, Direct steam cold water drainage, Total capacity – Cleveland Range SteamCraft 24-CDP-10 User Manual

Page 2: Clearance

Advertising
background image

UTILITY CONNECTIONS

ELECTRIC

115V - 1 Phase

Controls - 51 Watts

(NOT TO SCALE)

SECT.

IV

PAGE

22

0707

Litho in U.S.A.

DIRECT STEAM

COLD WATER

DRAINAGE

C

D

35 psi minimum
60 psi maximum

3

4

˝ Dia. NPT for

Condenser

1

1

2

˝ Dia.

Do not connect other units
to this drain.

Drain must not be located
beneath the steamer itself.

No PVC pipe for drain.

Steam supply:

Furnish

3

4

˝ IPS minimum line.

20 to 50 psi minimum required.

For pressures between 50 to 120 psi, on additional
Pressure Reducing Valve must be specified.

C

10 — 12˝ x 20˝ x 2

1

2

˝ Cafeteria Pans or

20 — 12˝ x 20˝ x 1˝ Cafeteria Pans or

2

6 — 12˝ x 20˝ x 4˝ Cafeteria Pans

TOTAL CAPACITY

(2 Compartments)

Electrical Supply

Drain: 1.50˝ Dia.

Water Supply for Condenser

3

8

˝ Dia. NPT

Steam Supply: 0.75˝ Dia.

A

B

C

D

Each Compartment has
capacity for:

• Five, 12˝ x 20˝ x 2

1

2

˝ deep

Cafeteria Pans.

WATER QUALITY

REQUIREMENTS

The quality of water varies
greatly from region to region.
Steam equipment generators
must be drained daily and
chemically descaled periodically
to ensure proper operation. To
minimize service problems
caused by the accumulation of
minerals and chemicals in water
review the following quality
guidelines with a local water
treatment specialist. Inlet water
that is beyond these specified
guidelines should be treated to
achieve these acceptable limits.
Total Dissolved Solids less than
60 ppm, Alkalinity less than 20
ppm, Silica less than 13 ppm,
pH factor greater than 7.5,
Chlorine less than 30 ppm.

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, ULC and UL/NSF#4.

CLEARANCE

Right - 3”, Left - 3”, Rear - 3”

(12” on control side if
adjoining wall or
equipment is over 30”
high for service access)

Contact factory for
variances to clearances.