Control Blocks and Interfaces

Control Blocks

A1

Full Feature Control Block

Part No. 436313

A6

Simple Control Block

Part No. 103862

Electrical Interfaces

(not included with control blocks)

C10

Part No. 438223

Comprises :
2 x M8 Proximity Switches PNP (NO)
2 x Plug-in Cables
2 x Solenoid Valves (NC)

C11

Part No. 438233

Comprises :
2 x M8 Proximity Switches PNP (NO)
2 x Plug-in Cables
1 x Solenoid Valve (NC)
1 x Solenoid Valve (NO)

C12

Part No. 438243

Comprises :
2 x M8 Proximity Switches NPN (NO)
2 x Plug-in Cables
2 x Solenoid Valve (NC)

C3

Part No. 104002

Comprises :
2 x M8 Proximity Switches PNP (NO)
2 x Plug-in Cables

C5

Part No. 104842

Comprises :
2 x M8 Proximity Switches NPN (NO)
2 x Plug-in Cables

Solenoid Valves
ALL 24V DC
NC – Valve normally closed
NO – Valve normally open

Proximity Switches
All 10-30V DC
NC – Normally closed
NO – Normally open

AFD60 / AFT60 Control Block

(Supplied fitted)

Electrical Inputs and Outputs

24VD.C. Switched Red
OV. Common Black
24VD.C. Switched Green
Switch Yellow
Switch Common White
Switch Blue

Air connection as above
except M port which is
negative at datum.
To invert signal use kit

Part No. 104822

Electrical Interface

Part No. 79532
24V DC
Comprises:
2 metre cable Adaptor
and O ring Interface block

Air Connections

R

Air Return Port – Connects to breather port in nose of tool to provide

extra retract capability with heavy front end attachments (1/8” BSP)

ST

Start Button – For manual operation and set-up

1

Remote Start Signal Port Pulse (M5)

SP

Manual Stop Button – Interrupts cycle and returns AFD to datum

P

Remote Stop Signal Port – Requires external signal pulse for

returning the unit to datum rest position (M5)

O

Air inlet (1/4” BSP or 1/4” NPT)

M

Work Cycle Complete Port – Used for sequence control with other

AFD’s clamps, index tables, etc (positive at datum position) (M5)

O

Depth Stop Signal Port – Used with external circuits such as dwell or

pecking (1/8” BSP)

Retract rate adjustment control
Advance rate adjustment control
Feed rate adjustment control

F

Feed port (1/8” BSP)

RN

Return port (1/8” BSP)

Electrical Connections
S1

Start solenoid

S2

Stop solenoid

SW1

Datum return (M8 x 1.00)

SW2

Depth position (M8 x 1.00)