Heater table (allen-bradley), With general electric switches, Heater table (general electric) – Cooper Bussmann EDSC2199 User Manual

Page 2

Advertising
background image

463

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright

©

2010 Cooper Crouse-Hinds

2C

2C

EDS Series Factory Sealed
Manual Motor Starting Switches
and Enclosures

Ordering Information
With Allen-Bradley Bulletin 600 Switches

Maximum HP Ratings

Poles

115–230
Volts AC

115–230
Votts DC

Cat. #

1

1 hp

A B BUL 600 TOX4

2

1 hp

3

/

4

hp

A B BUL 600 TOX5

Poles

Hub
Size in.

Dead end Cat. #

Through feed Cat. #

Single Gang

1

3

/

4

EDS2199

EDSC2199

1

EDS3199

EDSC3199

2

3

/

4

EDS21100

EDSC21100

1

EDS31100

EDSC31100

Two Gang

1

3

/

4

EDS2299

EDSC2299

1

EDS3299

EDSC3299

2

3

/

4

EDS22100

EDSC22100

1

EDS32100

EDSC32100

Heater Table (Allen-Bradley)

Max. Motor
Full-Load
Amps

Crouse-Hinds
Symbol Number

Max. Motor
Full-Load
Amps

Crouse-Hinds
Symbol Number

0.17

P1

2.92

P22

0.21

P2

3.09

P23

0.25

P3

3.32

P24

0.32

P4

3.77

P25

0.39

P5

4.16

P26

0.46

P6

4.51

P27

0.57

P7

4.93

P28

0.71

P8

5.43

P29

0.79

P9

6.03

P30

0.87

P10

6.83

P31

0.98

P11

7.72

P32

1.08

P12

8.24

P33

1.19

P13

8.9

P34

1.30

P14

9.6

P35

1.43

P15

10.8

P36

1.58

P16

12.0

P37

1.75

P17

13.5

P38

1.88

P18

15.2

P39

2.13

P19

2.40

P20

2.58

P21

With General Electric Switches

Maximum HP Ratings

Poles

115–230
Volts AC

115
Votts DC

230
Votts DC

Cat. #

1

1 hp

1 hp

1

/

4

hp

GE CR101 Y

2

1 hp

1 hp

1 hp

GE CR101 H

Poles

Hub Size
in.

Dead end Cat. #

Through feed Cat. #

Single Gang

1

3

/

4

EDS21093

EDSC21093

1

EDS31093

EDSC31093

2

3

/

4

EDS21094

EDSC21094

1

EDS31094

EDSC31094

Two Gang

1

3

/

4

EDS22093

EDSC22093

1

EDS32093

EDSC32093

2

3

/

4

EDS22094

EDSC22094

1

EDS32094

EDSC32094

Heater Table (General Electric)

Max. Motor
Full-Load
Amps

Crouse-Hinds
Symbol Number

Max. Motor
Full-Load
Amps

Crouse-Hinds
Symbol Number

.48

G2

3.01

G22

.53

G3

3.27

G23

.58

G4

3.56

G24

.65

G5

3.88

G25

.71

G6

4.22

G26

.78

G7

4.60

G27

.86

G8

5.00

G28

.95

G9

5.43

G29

1.04

G10

5.90

G30

1.14

G11

6.41

G31

1.25

G12

6.98

G32

1.37

G13

7.60

G33

1.49

G14

8.25

G34

1.63

G15

8.95

G35

1.78

G16

9.75

G36

1.95

G17

10.6

G37

2.13

G18

11.4

G38

2.32

G19

12.5

G39

2.53

G20

13.6

G40

2.76

G21

14.8

G41

16.0

G42

Cl. I, Div. 1 & 2, Groups B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7B*CD, 9EFG

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

*Add GB suffix. Seals must be installed within 1

1

/

2

" of each conduit opening for Group B usage.

➀ Includes one interchangeable heater. Select heater from the table
below individual listings and use symbol number as second section
of the Cat. No. Example: EDS2199-P5. Insert symbol 0 (zero) to omit
heater.

These heaters are for motors rated 40°C continuously. For motors
rated 50°C or 55°C, multiply full load motor current by 0.9 and use
this value to select heaters. Symbol 0 (zero) must be used to indicate
heater omitted.

Advertising