Seite #10 – CBC ZN-LN8048NHA User Manual

Page 10

Advertising
background image

v2.0 - English

10

The relay output allows for switching external devices. This control output can be used
interactively during an active connection with the camera. The contact can be programmed
as normally open (NO) or normally closed (NC) and it is possible to invert the mechanical
function by software setup.

The relay contact must not be subjected to a load of more than 40V and 0.8A.

Power Supply

This camera has no master power switch. When you have connected the power supply
unit to the device and insert the power plug into a socket, the device is powered on and
ready for operation.

Assigning the IP Address

Ø Start the ‘Jet Manager’program.
Ø Click on ‘scan’ icon.
Ø Select the desired ‘ZN-L8000’ and right-click to bring up the context menu.
Ø Click on “Change IP Address”.
Ø Click on “IP Pool”if you have not yet specified a valid IP address range and set it.
Ø Select “Set manually”and choose a valid IP address.
Ø Click on “OK”
Ø Wait few seconds and click again on ‘scan’ icon to view new IP address in the list.
Ø Select again the ‘ZN-L8000’ and right-click, selecting “View in Browser”to view the

camera in Microsoft Internet Explorer.

Day / Night Manual Control Function

Only the ZN-LN8048PHA and ZN-LN8048NHA Day / Night Models feature the N.O. input
terminal (#4). This terminal will manually switch the camera from color (open contact) to
B&W (closed contact). When this terminal is closed, the camera switches into Night Mode
and adjusts the DC iris by fixing the AES speed.
When the camera switches to Night Mode automatically, the DC iris is completely opened
and the AES speed is adjusted by the camera.

Advertising
This manual is related to the following products: