WIRING

PIN 4: BROWN: (-) AUX OUTPUT (TRUNK POP) or DOME LIGHT ILLUMINATION OUTPUT
This output is programmable for two modes of operation. See Programming Option Section.

Mode (1) DEFAULT: Provides a Ground pulse when button #3 (Trunk) on the remote transmitter is pushed to activate
a factory electric trunk release or other optional accessory.
Mode (2) ALTERNATE: Provides a Ground output for 30 seconds when the unlock button is pressed for use as a
dome light illumination output.

Note when using the Brown wire as a Trunk Pop, you may also need or want to program option #14 so the system
also provides an Unlock signal when the trunk pop is activated. This may help to prevent unnecessary triggering
of Factory Alarm systems or you may want the convenience of having the door unlock at the same time.

BROWN

85

86

30

87

Trunk Soleniod

Dome Light

BROWN WIRE: TRUNK OUTPUT or DOME LIGHT

OR *

(Default)

+12V CONSTANT

+12V CONSTANT

-OR-

Circuit

* Test activation circuit in vehicle.

Connect to+12V for Positive circuits

or Ground for Negative circuits. Relay