Carrier Access Thermidistat User Manual

Page 12

Advertising
background image

T H E R M I D I S TAT C O N T RO L C O N F I G U R AT I O N R E C O R D

Date

Owner/Operator

A) Hardware Configuration
Switch A ____ AC/HP Select. (OFF = AC)
Switch B ____ 1 or 2-Speed Compressor. (OFF = 1-Speed)
Switch C ____ Smart Recovery. (OFF = Enable)
Switch D ____ Installer Test. (OFF = Disable)

Thermidistat Model No.

B) Mode Settings

____ Hold (On or Off)
____ Mode (Off, Heat, Cool, Auto, Eheat)
____ Heating Set Point Value
____ Cooling Set Point Value
____ Fan (Auto or On)

C) Configuration Options

D) Schedule

E) Humidity Settings
Heat Mode Cool Mode

Selection

Set Point%

Display

Normal Humidify

_________

(hu)

Fan Humidify

_________

(hu, Fan)

Auto Humidify

_________

(hu, AUTO)

Auto and Fan Humidify

_________

(hu, AUTO, Fan)

Humidify Off

no set point

(hu, OF)

1

______ Anticipator (1-9: factory default = 3)

2

______ Clean Filter Timer (Off or 1-9: factory default = 2)

3

______ Fahrenheit or Celsius (F or C: factory default = F)

4

______ Fan On with W (Off or On: factory default = Off)

5

______ Variable Speed ICM Motor (Off or On: factory default = Off)

6

______ Cooling Lockout Below 55

°

F (Off or On: factory default = Off)

7

______ Variable Speed Superdehumidify (Off or On: factory default = Off, or Not Available)

8

______ Auxiliary Heat Lockout Setting (Off or 5-55

°

F: factory default = Off, or Not Available)

9

______ Intelligent Heat Staging Selection (Off or On: factory default = Off, or Not Available)

10

______ Dual Fuel Equipment Selection (Off or On: factory default = Off, or Not Available)

11

______ Balance Point Setting (Off or 5-55

°

F: factory default = Off, or Not Available)

12

______ Defrost Heat Select (0, 1, 2, 3: factory default = 0, or Not Available)

13

______ Room Temperature Offset (-5 to +5: factory default = 0)

14

______ Heat/Cool Dead Band (0 to 6: factory default = 2)

15

______ Enable Auto Mode (On or Off: factory default = On)

16

______ Enable Super Comfort Heat Mode (Off or On: factory default is Off, or not Available)

17

______ Enable Non-Programmable Operation (nP or P: factory default is P for programmable)

Mon

Tue

Wed

Thu

Fri

Sat

Sun

TIME HEAT COOL

TIME HEAT COOL

TIME HEAT COOL TIME HEAT COOL

WAKE

DAY

EVE

SLEEP

A99015

Selection

Set Point%

Display

Normal Dehumidify

_________

(d hu)

Cool to Dehumidify

_________

(d hu, COOL)

Dehumidify Off

no set point

(d hu, OF)

E) Vacation Humidity Settings
Heat Mode Cool Mode

Selection

Set Point%

Display

Normal Humidify

_________

(hu, OUT)

Auto Humidify

_________

(hu, OUT,AUTO)

Auto and Fan Humidify

_________

(hu, OUT,AUTO, Fan)

Humidify Off

no set point

(hu, OUT, OF)

Selection

Set Point%

Display

Normal Dehumidify

_________

(d hu, OUT)

Cool to Dehumidify

_________

(d hu,OUT,COOL)

Dehumidify Off

no set point

(d hu, OUT,OF)

Cut and Sa

v

e

f

or Customer File

Copyright 1999 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231

tstt23si

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

4

Tab

misc. misc.

PC 101

Catalog No. 03TS-TA17

Printed in U.S.A.

Form TSTAT-23SI

Pg 12

8-99

Replaces: TSTAT-19SI

Advertising