Installation instruction, Technical information for the installer – CDA HCC310 User Manual

Page 8

Advertising
background image

8

Installation Instruction

TECHNICAL INFORMATION
FOR THE INSTALLER

Before installing the cooktop, remove
the protective film.
This cooktop can be built into a
working surface 30 to 40 mm thick
and 600 mm deep.

In order to install the ceramic griddle
into the kitchen fixture, a hole with
the dimensions shown in fig. 3 has
to be made, keeping in considera-
tion the following:

✓ within the fixture, between the

bottom side of the ceramic griddle
and the upper surface of any
other appliance or internal shelf
there must be a clearance of at
least 30 mm;

✓ the ceramic griddle must be kept

no less than 300 mm away from
any side wall;

✓ the rear wall must be at least 50

mm from the ceramic griddle and
must withstand a temperature of
150°C.

✓ there must be a distance of at least

650 mm between the hob and
any wall cupboard or extractor
hood positioned immediately
above (see fig. 4)

✓ the coatings of the walls of the

unit or appliances near the
cooktop must be heat resistant (“X”
protection against heating in
compliance with standards EN
60335-2-6).

✓ Do not instal the appliance near

inflammable materials (eg.
curtains).

650 mm

450 mm

300 mm

490

510

270

288

50

+ 0

– 2

+ 0

– 2

Figure 3

Figure 4

Advertising