3-2 error codes, Error codes – Panasonic SPX900 User Manual

Page 90

Advertising
background image

90

7-3-2

Error Codes

The following error codes are displayed in the display window if
an error occurs in the camera:

5. P2 Card Fully Recorded

Display window
indication

All 7 bar indicators for remaining MEDIA capacity
start blinking.

WARNING lamp

Continues to light up until an operation is
performed.

Tally lamp

Continues to blink 4 times per second until an
operation is performed.

Viewfinder

The END indicator blinks.

Warning tone

Continues to beep until an operation is
performed.

Warning
description

The P2 cards are recorded to maximum capacity.

Recording/
playback operation

The recording stops.

Countermeasures

Delete the clips in the P2 card or insert a new P2
card.

8. Battery Nearly Empty

Display window
indication

One of the bars in the battery remaining indicator
starts blinking.

WARNING lamp

Blinks once per second.

Tally lamp

Blinks once per second.

Viewfinder

The BATT LED blinks.

Warning tone

Beeps 4 times per second.

Warning
description

The battery is about to run out.

Recording/
playback operation

Continues to operate.

Countermeasures

Replace the battery as required.

6. Recording Error

Display window
indication

“00:00:00:11” appears in the time code display
field.

WARNING lamp

Blinks 4 times per second while recording
continues.

Tally lamp

Blinks 4 times per second while recording
continues.

Viewfinder

The REC WARNING indicator lights up.
Even after recording is stopped, this display
continues to light up until the next operation is
performed.

Warning tone

Beeps 4 times per second while recording
continues.

Warning
description

Recording signal processing error.

Recording/
playback operation

Recording stops.

Countermeasures

Restart recording. Or, turn the power OFF and
turn it ON again, before starting recording.

9. P2 Card Nearly Full

Display window
indication

One of the bars for remaining MEDIA capacity
starts blinking.

WARNING lamp

Blinks once per second while recording
continues.

Tally lamp

Blinks once per second while recording
continues.

Viewfinder

The P2 card remaining capacity indicator blinks.

Warning tone

Beeps once per second while recording
continues.

Warning
description

The total remaining capacity of all the P2 cards is
two minutes or less.

Recording/
playback operation

Continues to operate.

Countermeasures

Replace the cards. If there is an empty card slot,
insert a new card.

7. Low Wireless Signal Reception

Display window
indication

No display.

WARNING lamp

Blinks 4 times per second. (During pause and
recording)

Tally lamp

Blinks 4 times per second while recording
continues.

Viewfinder

The WIRELESS RF indicator lights up while
recording continues.

Warning tone

Beeps 4 times per second while recording
continues.

Warning
description

This error indicates poor wireless audio reception
conditions.

Recording/
playback operation

Continues to operate without receiving the
wireless microphone signal.

Countermeasures

Check the microphone power supply and the
reception status of the wireless receiver.

Code No.

Description

E-11

Video initialisation error

E-27

Recording control error

E-30

P2 card removal error

E-38

P2 streaming microcontroller error

E-3F

Microprocessor error in the camera control circuit.

E-6F

Reference signal error.