<Note>

The remaining battery capacity for digital batteries is displayed
as % inside the viewfinder (PRO14/TRIM14/HYTRON50/
HYTRON100/HYTRON120/DIONIC90/DIONIC160/NP-L50).
The BATT NEAR END alarm, however, is triggered according to
the setting on the <BATTERY SETTING1> screen, regardless of
the % indication.

The ____ in the Adjustable Range column indicates the preset
mode.

Items/

Data Saved

Adjustable

Range

Remarks

DIONIC90

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

13.6

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

DIONIC160

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

13.3

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

HP-90L

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

12.4

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

BP-H120

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

11.5

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

NP-L50

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

13.0

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

Items/

Data Saved

Adjustable

Range

Remarks

ENDURA50

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

13.1

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

ENDURA80

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

13.5

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

BP-L60/90

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

11.2

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

Advertising