Troubleshooting chart, Hu3501 – Campbell Hausfeld IN630800AV User Manual

Page 7

Advertising
background image

Symptom

Possible Cause(s)

Corrective Action

1. Loss of power or overheating

2. No electrical power
3. Blown fuse
4. Breaker open
5. Thermal overload open

6. Pressure switch bad

1. Low voltage
2. Wrong gauge wire or length of

extension cord

3. Shorted or open motor winding
4. Defective check valve or unloader

1. Incorrect size fuse, circuit overloaded

2. Wrong gauge wire or length of

extension cord

3. Defective check valve or under loader

1. Low voltage
2. Clogged air filter
3. Lack of proper ventilation/room

temperature too high

4. Wrong gauge wire or length of

extension cord

1. Loose connections (fittings, tubing,

etc.)

2. Loose drain lock
3. Check valve leaking

1. Excessive water in air receiver
2. High humidity

1. Defective pressure switch
2. Excessive air usage

3. Check valve leaking

Loose mounting bolts

1. Broken inlet valves
2. Intake filter dirty
3. Connections leaking

1. Check for proper use of extension cord (see

EXTENSION CORDS, page 3)

2. Plugged in? Check fuse/breaker or motor overload

3. Replace blown fuse
4. Reset, determining why problem happened
5. Motor will restart when cool; turn off compressor and

wait 20 minutes.

6. Replace

1. Check with voltmeter
2. Check gauge chart, under Operation for proper

gauge wire and cord length

3. Replace motor
4. Replace or repair

1. Check for proper fuse, use time-delay fuse.

Disconnect other electrical appliances from circuit or
operate compressor on its own branch circuit

2. Check gauge chart, under Operation

3. Replace or repair

1. Check with voltmeter
2. Clean filter (see Maintenance section)
3. Move compressor to well ventilated area

4. Check gauge chart, under Operation

1. Check all connections with soap and water solution

and tighten

2. Tighten
3. Disassemble check valve assembly, clean or replace

Do not disassemble check valve

with air in tank; bleed tank

1. Drain receiver
2. Move to area of less humidity; use air line filter

1. Replace switch
2. Decrease air usage; compressor not large enough for

a requirement

3. Disassemble check valve assembly, clean or replace

Tighten

1. Have authorized service representative repair unit
2. Clean or replace intake filter
3. Tighten connections

Compressor will not run

Motor hums but cannot
run or runs slowly

Fuses blow/circuit
breaker trips repeatedly

Thermal overload
protector cuts out
repeatedly

Air receiver pressure
drops when compressor
shuts off

Excessive moisture in
discharge air

Compressor runs
continuously

Compressor vibrates

Air output lower than
normal

HU3501

7

www.chpower.com

Troubleshooting Chart