NOTES: For complete product data, refer to the Neo-Ray Specification Binder. Specifications and dimensions subject to change without notice. Products may be

modified for use in international markets. Please contact your Cooper Lighting Sales Representative for availability and ordering information.

739

COOPER LIGHTING

GEO

89-DIW

83-DW

80-IW

D I R E C T- I N D I R E C T

W
ALL

Construction
20-gauge steel housing. Nominal 3’, 4’, 6’ or 8’
illuminated sections.

End Caps
20-gauge steel construction.

Shielding
White bold baffle louver. White acrylic diffuser.
Prismatic acrylic lens. Parabolic baffle.

Electrical
120, 277, 347 or Universal Voltage electronic ballast.
Fixtures and electrical components certified to UL
and CUL standards.

Finish
Durable, low gloss, white, powder coated acrylic
finish.

Mounting
Wall mounted.

6-1/4"

[159mm]

6" [153mm]

1/2" [13mm]

89DIW

83DW

80IW

GEO 89 DIW FEATURES

• Direct – indirect light

distribution.

• The light is continuous and

unbroken.

• Die formed steel housing,

nominal illuminated sections
3’, 4’, 6’ and 8’.

• Runs provided to the nearest

foot.

• Patterns are formed by

butting standard sections.

• Selection of 4 light diffuser

options.

• Rigid ‘U’ shaped double

formed trim with 3/8”
regress soft lit edge.

• Housings may be special

ordered custom finished.

GEO 80 IW features

• Indirect light distribution.

GEO 83 DW features

• Direct light distribution.

ORDERING INFORMATION:

Sample number: 83DW-2T8-36-2EB-SI-S79

Series

89DI=Direct/Indirect

83D=Direct

80I=Indirect

Mounting

W=Wall

Number of Lamps

(per cross section) (not included)

1=1 Lamp (T8, T5, T5HO)

2=2 Lamps (T8, T5, T5HO)

Lamp Type

T8

T5

T5HO

Run Length

Overall Nominal Run Length__ft. (Any combination of 8’, 6’, 4’ and 3’
sections)

Voltage

1

1=120V

2=277V

3=347V

U=Universal

Ballast

EB=Electronic Ballast (Standard)

DB=Dimming Ballast

Switching

SI=Single Switching

DU=Dual Switching (2 Lamps)

Emergency

EM=Emergency Pack (Consult Factory)

Fusing

GLR

GMF

Shielding

(Available for 83 and 89 only)

S22=White Acrylic Diffuser with Mullion
S72=White Bold Baffle
S58=KSH-12 Clear Acrylic Prismatic Lens with Mullion
S79=Semi-Specular Aluminum Parabolic Baffle

1 Due to various constraints, some options may not be combined with others.

S22 Acrylic Diffuser

S58 Acrylic Lens

S72 Bold Baffle

S79 Parabolic Baffle

30" [762mm]

30" [762mm]

72" [1829mm]

96" [2438mm]

42" [1067mm]

42" [1067mm]

36" & 48"

[914mm] & [1219mm]

ILLUMINATED PATTERNS ARE PROVIDED IN
1 FOOT INCREMENTS PLUS 7 3/4" CONSULT
FACTORY FOR CONTINUOUS RUN MOUNTING
BOX LOCATIONS

ILLUMINATED
90˚ MITERED CORNER

6"

[152mm]

6"

[152mm]

6"

[152mm]

6"

[152mm]

6"

[152mm]

6"

[152mm]

6"

[152mm]

6"

[152mm]

S T A N D A R D L U M I N A I R E L E N G T H S *

NEO-RAY

Advertising