Cooper Lighting ADY080864 User Manual

Exploded view and part call-out, Securing power side pendant to ceiling attention, Securing non-power side pendant

Advertising
background image

Canopy

Appropriate fasteners
(by others)
(x2)

Mounting plate

1. To mount non-power side pendant, use dimensions provided
on page three(3).
2. Using appropriate fasteners(by others), secure mounting plate
to structure/ bracing in ceiling.

End cap

#8-32 x.75"
Cap screw
(x2)

1/4-20 x1"
Aiming screw

3/8-16 x1"
Hex end screw
(x2)

Fixture door

Mounting bracket

Canopy

Exploded View and Part Call-Out

J-box
(by others)

Securing Power side Pendant to Ceiling

Attention:

All extra large fixtures require additional bracing/structure around J-box to support fixture.

Securing non-Power side Pendant

Pendant length dependant
on order(multiple sections
may be required, consult
factory for coupler and
safety wire installation
requirements).

Appropriate fasteners
(by others)
(x2)

Canopy

J-box
(by others)

Mounting plate

1. Remove canopy and allow it slide down pendant.
2. Using appropriate fasteners(by others), secure mounting
plate to structure/ bracing around J-box.
3. For mounting plate dimensions refer to page three(3).

Warning

: Before starting any work ensure

that all sources of power are turned off. All

work must meet local/national codes and be

performed by a certified electrician. Do not

mount fixtures vertically.

Installation Instructions

1.

Sheet 1 of 3

Roundel, XL

INDOOR

PS

(Pendant Swivel)

Visor and Non-Visor

2.

ADY080864 REV B(ECN080377)

Advertising