Ii. option programming tables – CompuSTAR CM4200DX User Manual

Page 2

Advertising
background image



Note 12: Updating Controller Module
Look at the wiring chart of the module. If it is marked “V”, you have Version 12. If you have any other version, it will show the version
number. Please check

www.compustar.com

to find out if there are any new updates. If there is any, we recommend you to update the module

before installation. All three modules, CM4000, CM4200(DX) and CM4300, use same software program.

Updating the Module.

1.

You need to have a USB Uploader, the part number CST-USB-ASSY (3 components – a USB cable, a USB Module and a double head data cable.) If you already have a USB Uploader for
OP500 or iDataLink, order the double head data cable, part number USB-DC2 for free of charge. You need to pay freight. USB-DC2 is a cable connecting USB module to CompuStar and has
two connectors instead of one



Or, for a temporary use, you may modify any of the CompuStar antenna cable you have now. See below.

2. Plug in USB connector to available USB port on computer. Do not have anything (idatalink, CM4000, OP500 etc) connected to the updater when connecting it to the computer.
3. Windows will automatically find drivers for the USB upload cable.
4. To retrieve software for updating, please email:

[email protected]

. Please write “request for update software” in subject. You can also go to

www.compustar.com

.

Now you are ready to update your control module
5. You will need to first identify what COM port your USB device is set up to use. To do this, Right-click on "My Computer" and go to "Properties". Once the properties window is on the screen,
click the "Hardware" tap at the top of the window. Then in the main body of the window, click on the Device Manager" button. Under "Ports (COM & LPT)" There should be a device called
"USB Serial Port (COM?)", the number that is in place of the question mark is your selected com port. Disconnect the main harness; the system can not have power while you are
attempting to update its software.
6. The LED/Secure Valet switch must be connected.
7. Connect to the RS232 port of CompuStar.
8. Open the "CM4000 v12" folder, for example, and hold the LED/Valet switch button down while you double-click the file that matches your com port. Example: I use COM5 so I would use
"Update-COM5.bat". Once the LED in the LED/Valet switch starts flashing, you can let go of the button. After it is finished, just disconnect the CM4000 from the USB Updater and connect the next
CM4000 if you have more to do.

II.

Option Programming Tables

Option Programming and Secure Valet are available only when “DISARMED”.
Special Option Group #1 and #2 can be programmed only with OP500.

OPTION GROUP 1

Setting

Applicable To

#1 Feature

Default(I) Optional(II)

Optional(III)

Optional(IV)

CM4000

CM4200-DX

CM4300

1-1

Unlock before, Lock after, starting.

Off

On

Lock After Start Only

V

V

1-2

Lock / Unlock pulse duration.

0.8 sec

2.5 sec

0.125 sec

3.5 sec

V

V

V

1-3

Driver's priority unlock

Off

On

V

V

V

1-4

Double pulse unlock.

Off

On

V

V

V

1-5 Rearm

Output

After Start Shutdown and

First Lock

After Start Shutdown and

Every Lock

V

V

V

1-6

Reservation Lock (Manual transmission)

Locks When Reservation

Mode is Set

Does Not Lock When

Reservation is Set

Reservation Sets 10 Seconds

After the Last Door is

Closed

V

V

1-7

Unlock / Disarm With Trunk Release

Unlock, Factory Disarm, and

Trunk Release

Factory Disarm, Trunk

Release Only

Trunk Release Only

V

V

V

1-8

Locking while in Passive Arming

Passive locking w/ Passive

Arming

No Passive Locking w/

Passive Arming

V

V

V

1-9

Ignition controlled door locks

Off

On

RPM Locks (Tach Sensing

Mode Only)

V

V

V

1-10

Auto Relock (If a door is not opened within

this amount of time.)

Off

30 sec

60 sec

5 min

V

V

V

1-11

Ignition / Accessory Out Upon Unlock

Off

Ignition Pulse-same timing as

disarm pulse

Acc Pulse-same timing as

disarm pulse

Ig and Acc Pulse-same
timing as disarm pulse

V

V

V

OPTION GROUP 2

Setting

Applicable To

#2 Feature

Default(I) Optional(II)

Optional(III)

Optional(IV)

CM4000

CM4200-DX

CM4300

2-1

Min. Crank Time

Standard

+0.2 Seconds to Crank Time

+0.6 Seconds to Crank Time

(Voltage Sensing Only)

V

V

2-2 Turbo

mode.

Off

2 Min

1Min 4

Min

V

V

2-3

Diesel timer.

Wire

3~99sec (10sec Default)

V

V

2-4

Trigger Start Off Single

Pulse Double

Pulse

V

V

2-5

Cold Start with Thermistor Assembly Off On

V

V

2-6

Timer Start, or, Minimum Interval Between

Cold Starts

3 Hour (4 minute runtime,

double for Diesel)

1.5 Hour(4 minute runtime,

double for Diesel)

Reservation

(Runtime 2-7)

24 Hour Repeat with Cold

Starting of 2-8

(Runtime 2-7)

V

V

2-7

Remote Start Runtime

15 Min

25 Min

45 Min

3 Min

V

V

2-8

Temperature of Cold Starting

Off

-10° C / 14° F

-5° C / 23° F

0° C / 32° F

V

V

2-9

Temperature of Hot Starting

Off

30° C / 86° F

35° C / 95° F

40° C / 104° F

V

V

2-10

Engine Sensing Tach Alternator

No Connection – Voltage

Not for Manual

Transmissions

V

V

2-11

Turbo, Remote Start Runtime Extension w/ #1

for 2 seconds

No Yes

V

V

OPTION GROUP 3

Setting

Applicable To

#3 Feature

Default(I) Optional(II)

Optional(III)

Optional(IV)

CM4000

CM4200-DX

CM4300

3-1

Parking lights While Remote Started

Constant Output

Flashing Output

Off

V

V

3-2

Dome Light output Off Factory

Rearm 45

sec

Factory Rearm + 45 Sec

V

V

V

3-3

Dome Light Delay Off 5

sec 45

sec Auto

V

V

V

3-4

Starter-Kill relay. Anti-Grind

Anti-Grind + Starter Kill

Anti-Grind + Passive

Starter Kill

V

V

3-5 Anti-Jacking

Starter-kill

Ignition-Kill (no

Anti-Grind)

Auto kill (Auto-door locks

Off)

Canadian Remotes w/ AUTO

Function Only

Auto kill (Auto-door locks

On)

Canadian Remotes w/ AUTO

Function Only

V

V

3-6

Factory Alarm Option Off

On (4200DX Only)

V

3-7

Siren Duration (Upon Alarm Trigger)

30 sec

60 sec

120 Sec

Chirps for 20 seconds

V

V

3-8

Horn Output

On Double Lock Only

On Lock and Unlock

On Lock, Unlock, and Start

On Double Lock and Start

V

3-9

Horn Output (4000/4300) When Alarm Is

Triggered

Pulsed Output

(Horn)

Constant Output

(Secondary Siren)

V

V

V

3-10

Valet

Key 5 times, or Remote

(I+III) while Ignition is On

Key 5 times or Remote

(I+III)

Secure Valet(Default code

3,3)

V

V

V

3-11

Channel Expander Mode

Disabled

Enabled

V

V

V

3-12

Passive Arming with Channel Expander

enabled

No Passive Arming

Passive Arming

V

V

V

OPTION GROUP 4

Setting

Applicable To

#4 Feature

Default(I) Optional(II)

Optional(III) Optional(IV)

CM4000

CM4200-DX

CM4300

4-1

Aux 1 output

0.5sec

Latch

20 sec

Program

V

V

V

4-2

Aux 2 output

0.5sec

Latch

60 sec

Program

V

V

V

4-3

Aux 1 output Control

By Remote

Arm

Disarm

Panic

V

V

V

4-4

Aux 2 output Control

By Remote

Arm

Disarm

Panic

V

V

V

4-5

Secure Aux Output (1 and 2 Only) On Off

V

V

V

4-6

Auxiliary Input 1

Prewarn

Trigger

(-)Disarm

V

V

V

4-7

Auxiliary Input 2

Trigger

Prewarn

(-)Arm

V

V

V

4-8

Extended Accessory After Ign Shutoff Off 10

sec 30

sec

Until Door Open (1 min max)

V

V

V

4-9

Key Sense or Glow Plug input

Glow Plug Input

Key Sense Input

V

V

4-10

Trigger Start or Closed Loop System Input

Trigger Start input

Closed Loop System Input

V

V

V

SPECIAL OPTION GROUP #1

Applicable To

1

Feature

Setting Value [seconds]

CM4000

CM4200-DX

CM4300

1 Diesel

timer

3 ~ 99

V

V

2

AUX1 output time

1 ~ 100

V

V

V

3

AUX2 output time

1 ~ 100

V

V

V

4

AUX3 output time

1 ~ 100

V

V

5

AUX4 output time

1 ~ 100

V

V

6

AUX5 output time

1 ~ 100

V

V

7

AUX6 output time

1 ~ 100

V

V

8

AUX7 output time

1 ~ 100

V

V

SPECIAL OPTION GROUP #2

Applicable To

Feature

Setting Value

2

Programmable Output Connector

0[Default]

1~12

CM4000

CM4200-DX

CM4300

1

POC #1

2nd LIGHT

V

V

V

2

POC #2

2nd START

2nd Light[1], 2nd Start[2], 2nd IG1[3],

2nd Acc[4], Status Out[5], Rearm Out[6],

V

V

3-10 New in 4000 series.
To avoid accidental entry to
Valet Mode, you need to
have IG on while I+III are
pushed

Advertising