Operating Instructions

Alternator field is not energized

Low output voltage with no load

High output voltage with no load

Low output voltage under load

Erratic output voltage

Noisy operation

1. Engine speed is too slow

2. Open, shorted, or incorrect wiring

3. Faulty capacitor

4. Open or shorted field windings

5. Open diodes

1. Engine speed is too slow

2. Open diodes

3. Faulty capacitor

4. Open or shorted field windings

1. Faulty capacitor

2. Engine speed is too fast

1. Open diode

2. Engine speed too slow at full load

3. Excessive load applied

1. Unbalanced engine

2. Dirty, corroded, or loose wiring

connection

3. Unstable load applied

1. Loose generator or engine bolt

2. Short circuit in generator field or

load

3. Faulty bearing

1. Adjust engine speed ✽

2. Referring to the wiring diagram,

clean and reconnect all wiring ✽

3. Replace capacitor ✽

4. Test winding resistance, replace

field winding if necessary ✽

5. Test diodes, replace if necessary ✽

1. Adjust engine speed ✽

2. Test diodes, replace if necessary ✽

3. Replace capacitor ✽

4. Test winding resistance, replace

field winding if necessary ✽

1. Replace capacitor ✽

2. Adjust engine speed ✽

1. Test diodes, replace if necessary ✽

2. Adjust engine speed ✽

3. Reduce the applied load

1. Refer to engine manual

2. Referring to the wiring diagram,

clean and reconnect all wiring ✽

3. Remove all loads, then apply each

one individually to determine which
one is causing erratic function

1. Tighten all mountings

2. Test winding resistance, replace

field winding if necessary ✽

Test load devices for shorts. Replace
defective load device.

3. Replace bearing

✽ These diagnostic and repair procedures should be performed by an authorized service center.