Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Ovens

FL-2270

Rev. 10 (4/08)

Page 7 of 13

5925 Heisley Road • Mentor, OH 44060-1833

MAINTENANCE INSTRUCTIONS:

TROUBLE-SHOOTING GUIDE

PROBLEM

POSSIBLE CAUSE

SOLUTION

Humidity is low

1. Water in pan may be low
2. Thermostat set too low

1. Add water
2. Turn up thermostat

Cabinet does not heat,
or doesn’t heat properly

1. Fuse
2. Control
3. Sensor
4. Heater contactor
5. Loose wiring at heater contactor
6. On/Off Switch

1. Replace
2. Replace
3. Replace
4. Replace
5. Replace
6. Replace

Blowers do not operate

1. On/Off Switch
2. Fuse
3. Blower
4. Control

1. Replace
2. Replace
3. Replace
4. Replace

Heaters will not shut off

1. Thermostat
2. Contactor

1. Replace
2. Replace

Vent fan does not shut off

1. Vent fan switch defective
2. Control compartment is still hot.

1. Replace
2. Wait until it cools. Check
“Heaters will not shut off.”

Vent fan does not operate
(See Note)

1. Fuse
2. Vent fan switch defective
3. Vent fan defective

1. Replace
2. Replace
3. Replace

WARNING

IF UNIT GETS TOO HOT OR WON’T SHUT OFF, DISCONNECT

POWER AT BRANCH PANEL. DO NOT UNPLUG CORD!

1. Cord is unplugged from wall outlet.

2. Circuit breaker/fuse to wall outlet is blown.

3. Switch is turned off.

4. Thermostat is turned off, or is set too low.

If hot unit is NOT working, fi rst check the following causes:

NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement

of electrical components must be done by a qualifi ed electrician.