Compaq AA-RHGWC-TE User Manual

Page 328

Advertising
background image

_____________________

Note

_____________________

You may have problems if the member system supports the
bus_probe_algorithm

console variable and it is not set to

new

. See Section 2.3.2.

The KZPBA-CB UltraSCSI host adapter:

Is a high-performance PCI option connecting the PCI-based host system
to the devices on a 16-bit, ultrawide differential SCSI bus.

Is a single-channel, ultrawide differential adapter.

Operates at the following speeds:

5 MB/sec narrow SCSI at slow speed

10 MB/sec narrow SCSI at fast speed

20 MB/sec wide differential SCSI

40 MB/sec wide differential UltraSCSI

______________________

Note

_______________________

Even though the KZPBA-CB is an UltraSCSI device, it has an
HD68 connector.

Use the steps in Table 10–2 to set up a KZPSA-BB or KZPBA-CB host bus
adapter for a TruCluster Server cluster that uses radial connection to a
DWZZH UltraSCSI hub with an HSZ40 or HSZ50 RAID array controller.

Table 10–2: Installing the KZPSA-BB or KZPBA-CB for Radial Connection
to a DWZZH UltraSCSI Hub

Step

Action

Refer to:

1

Ensure that the KZPSA-BB internal termination
resistors, Z1, Z2, Z3, Z4, and Z5 are installed.

Section 10.1.4.4,
Figure 10–1, and KZPSA
PCI-to-SCSI Storage
Adapter Installation
and User’s Guide

Ensure that the eight KZPBA-CB internal
termination resistor SIPs, RM1-RM8 are installed.

Section 4.3.3.3,
Figure 4–1, and
KZPBA-CB PCI-to-Ultra
SCSI Differential Host
Adapter User’s Guide

10–4 Configuring Systems for External Termination or Radial Connections

to Non-UltraSCSI Devices