Introduction

~ Controls and Connections

4

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Rear view

A.

Power. The AC power cord input is a NEMA-type connector allowing

100–240VAC, 50/60Hz.

B.

G-Link In, Out. This RJ-45 connector is used to connect the AP10 to the

AP800 for control. AP-Ware is capable of accessing and controlling a

G-Link local area network (LAN) of up to eight AP800/AP400 units and

16 AP10 units. G-Link supports a distance of up to 20 feet between each

connected unit.

C.

Remote. This DB-25 connector provides control and status of the AP10 and

unbalanced audio. See Appendix B for pinouts.

D.

Transmit Input. This Phoenix connector is used to connect transmit audio

(input) from the AP800 to the AP10, which is then sent to the telephone

line.

E.

Receive Output. This Phoenix connector is used to connect receive audio

(telephone participant audio) from the AP10 to the AP800.

F.

Telco Line. This RJ-11 connector provides connection of a standard analog

telephone line to the hybrid.

G.

Telco Set. This RJ-11 connector allows connection to a standard telephone

set. Tip and ring from the phone line are present at this connector when the

hybrid is in its off state. Tip and ring from the phone line are not present at

this point when the hybrid is in its on state.

A

B

C

D

E

F G

Figure 1.3. AP10 rear-panel connectors