Tsk wall stat kit – Louisville Tin and Stove VCR501A-H User Manual

Page 14

Advertising
background image

TSK WALL STAT KIT

OPTIONAL

(VC/VCR-H SERIES HEATERS)

WALL THERMOSTAT INSTALLATION INSTRUCTIONS

Your heater can be re-wired to operate with a millivolt wall thermostat by your installer. See wiring diagram
below for correct wiring.

NOTE: Do not disconnect the wire from the blocked flue switch to the “TH” terminal on the gas valve.

STEP 1.

Disconnect wire leading from Part #70080 (Bulb Control Switch) from valve.

STEP 2.

Cut the remaining wire leading from Part #70080 (Bulb Control Switch) to the blocked flue
switch, leaving its end connected to the blocked flue switch and leaving enough length to reach
the gas valve. Strip 1/2” of the insulation from the cut end of the wire.

STEP 3.

Connect one leg of thermostat wire to the “TH/PP” terminal on the gas valve.

STEP 4.

Connect second leg from the thermostat to the stripped wire coming from the blocked flue
switch. Secure this connection inside the heater cabinet.

STEP 5.

Secure both red wires from blocked flue switch inside heater cabinet. Make sure none of the

wires have enough slack to lay against the heat exchanger or draft hood.

Page 14

THERMOSTAT

OPTIONAL

PILOT

GENERATOR

WIRE

NUT

(Not provided)

BLOCKED

FLUE SWITCH

Advertising
This manual is related to the following products: