General troubleshooting, Eneral, Roubleshooting – Chauvet DMX-800 User Manual

Page 15

Advertising
background image

General Troubleshooting

Applies to

Symptom Solution(s)

Lights

Foggers

& Snow

Controllers

Dimmers

& Chaser

Auto shut off

Check fan thermal switch reset

9

Beam is very dim or
not bright

Clean optical system or replace lamp
Check 220/110v switch for proper setting

9

Breaker/Fuse keeps
blowing

Check total load placed on device

9

Chase is too slow

Check users manual for speed adjustment

9

9

9

Device has no power

Check for power on Mains.
Check device’s fuse. (internal and/or external)

9

9

9

Fixture is not
responding

Check DMX Dip switch settings for correct addressing
Check DMX cables
Check polarity switch settings

9

Fixture is on but
there is no
movement to the
audio

Make sure you have the correct audio mode on the
control switches. If audio provided via ¼” jack, make
sure a live audio signal exists
Adjust sound sensitivity knob

9

9

9

Lamps cuts off
sporadically

Possible bad lamp or fixture is overheating.
Lamp may be at end of its life.

9

Light will not come
on after power failure

Some discharge lamps require a cooling off period
before the electronics in the fixture can kick start it
again, wait 5 to 10 minutes before powering up

9

Loss of signal

Use only DMX cables
Install terminator
Note: Keep DMX cables separated from power cables
or black lights.

9

9

9

9

Moves slow

Check 220/110v switch for proper setting

9

No flash

Re-install bulb, may have shifted in shipping

9

No laser output

Bounce mirror motor may have shifted during shipping,
readjust

9

No light output

Check slip ring & brushes for contact
Install bulb
Call service technician

9

Relay will not work

Check reset switch
Check cable connections

9

Remote does not
work

Make sure connector is firmly connected to device

9

9

Stand alone mode

All Chauvet lighting fixtures featuring stand-alone
functions do not require additional settings, simply
power the fixture and it will automatically enter into this
mode

9

If you still have a problem after trying the above solutions, please contact CHAUVET Technical