Operation guide 3410 – G-Shock 3410 User Manual

Page 13

Advertising
background image

E-96

Correct altitude readings are not possible.
Relative altitude is calculated based on changes in barometric pressure readings by the pressure sensor.
To minimize the chance of reading error due to changes in barometric pressure, you should update the
reference altitude value before setting off on a trek or any other activity where you plan to take altitude
readings. For more information, see “To specify a reference altitude value” (page E-44).

ERR appears on the display after I perform 2-point calibration.
If - - - appears and then changes to ERR (error) on the calibration screen, it means that there is something
wrong with the sensor.

If ERR disappears after about one second, try performing the calibration again.

If ERR keeps appearing, contact your original dealer or nearest authorized CASIO distributor to have

the watch checked.

Whenever you have a sensor malfunction, take the watch to your original dealer or nearest authorized
CASIO distributor as soon as possible.

What causes incorrect direction readings?

Incorrect 2-point calibration. Perform 2-point calibration (page E-52).

Nearby source of strong magnetism, such as a household appliance, a large steel bridge, a steel

beam, overhead wires, etc., or an attempt to take direction readings on a train, boat, etc. Move away
from large metal objects and try again. Note that digital compass operation cannot be performed inside
a train, boat, etc.

E-97

What causes different direction readings to produce different results at the same location?
Magnetism generated by nearby high-tension wires is interfering with detection of terrestrial magnetism.
Move away from the high-tension wires and try again.

Why am I having problems taking direction readings indoors?
A TV, personal computer, speakers, or some other object is interfering with terrestrial magnetism
readings. Move away from the object causing the interference or take the direction reading outdoors.
Indoor direction readings are particularly diffi cult inside ferro-concrete structures. Remember that you will
not be able to take direction readings inside of trains, airplanes, etc.

The barometric pressure differential pointer does not appear on the display when I enter the

Barometer/Thermometer Mode.

This could indicate sensor error. Try pressing

B again.

The barometric pressure differential pointer is not displayed when the displayed current barometric

value is outside of the allowable measurement range (260 to 1,100 hPa).

World Time Mode

The time for my World Time City is off in the World Time Mode.
This could be due to incorrect switching between standard time and daylight saving time. See “To specify
standard time or daylight saving time (DST) for a city” (page E-76) for more information.

Charging

The watch does not resume operation after I expose it to light.
This can happen after the power level drops to Level 5 (page E-11). Continue exposing the watch to light
until the battery power indicator shows H or M.

E-98

Time Calibration Signal

The information in this section applies only when LIS, LON, MAD, PAR, ROM, BER, STO, ATH, MOW,
HKG, BJS, HNL, ANC, YVR, LAX, YEA, DEN, MEX, CHI, NYC, YHZ, YYT, TPE, SEL, or TYO is selected
as the Home City. You need to adjust the current time manually when any other city is selected as the
Home City.

The display shows the ERR indicator when I check the result of the latest receive operation.

Possible Cause

Remedy

Page

You are wearing or moving the

watch, or performing a button
operation during the signal
receive operation.

The watch is in an area with

poor reception conditions.

Keep the watch in an area where reception conditions are good
while the signal receive operation is performed.

E-17

You are in an area where signal
reception is not possible for
some reason.

See “Approximate Reception Ranges”.

E-16

The calibration signal is not
being transmitted for some
reason.

Check the website of the organization that maintains the time

calibration signal in your area for information about its down times.

Try again later.

The current time setting changes after I set it manually.
You may have the watch confi gured for auto receive of the time calibration signal (page E-18), which will
cause the time to be adjusted automatically according to your currently selected Home City. If this results
in the wrong time setting, check your Home City setting and correct it, if necessary (page E-31).

E-99

The current time setting is off by one hour.

Possible Cause

Remedy

Page

Signal reception on a day for
switching between standard
time/daylight saving time (DST)
may have failed for some reason.

Perform the operation under “To get ready for a receive operation”.
The time setting will be adjusted automatically as soon as signal
reception is successful.

E-17

If you are unable to receive the time calibration signal, change the
standard time/daylight saving time (DST) setting manually.

E-33

Auto receive is not performed or you cannot perform manual receive.

Possible Cause

Remedy

Page

The watch is not in the
Timekeeping Mode or World
Time Mode.

Auto receive is performed only while the watch is in the Timekeeping
Mode or World Time Mode. Switch to either of these two modes.

E-26

Your Home City setting is wrong. Check your Home City setting and correct it, if necessary.

E-31

There is not enough power for
signal reception.

Expose the watch to light to charge it.

E-10

Signal reception is being performed successfully, but the time and/or day is wrong.

Possible Cause

Remedy

Page

Your Home City setting is wrong. Check your Home City setting and correct it, if necessary.

E-31

The DST setting may be
incorrect.

Change the DST setting to Auto DST.

E-31

E-100

Specifi cations

Accuracy at normal temperature: ±15 seconds a month (with no signal calibration)
Timekeeping: Hour, minutes, seconds, p.m. (P), year, month, day, day of the week

Time format: 12-hour and 24-hour
Calendar system: Full Auto-calendar pre-programmed from the year 2000 to 2099
Date/Time Records: Up to 40 records (shared storage with altitude, bearing, and barometric pressure/

temperature records)

Other: Two display formats (day of the week screen, barometric pressure graph screen); Home City

code (can be assigned one of 48 city codes); Standard Time / Daylight Saving Time (summer time)
Year display on setting screen only.

Time Calibration Signal Reception: Auto receive 6 times a day (5 times a day for the Chinese calibration

signal) ; Remaining auto receives cancelled as soon as one is successful; Manual receive;
Receive Mode

Receivable Time Calibration Signals: Mainfl ingen, Germany (Call Sign: DCF77, Frequency: 77.5

kHz); Anthorn, England (Call Sign: MSF, Frequency: 60.0 kHz); Fort Collins, Colorado, the
United States (Call Sign: WWVB, Frequency: 60.0 kHz); Fukushima, Japan (Call Sign: JJY,
Frequency: 40.0 kHz); Fukuoka/Saga, Japan (Call Sign: JJY, Frequency: 60.0 kHz) ; Shangqiu
City, Henan Province, China (Call Sign: BPC, Frequency: 68.5 kHz)

Altimeter:

Measurement range: –700 to 10,000 m (or –2,300 to 32,800 ft.) without reference altitude
Display range: –10,000 to 10,000 m (or –32,800 to 32,800 ft.)

Negative values can be caused by readings produced based on a reference altitude or due to
atmospheric conditions.

Display unit: 1 m (or 5 ft.)

E-101

Current Altitude Data: Every second for the fi rst 3 minutes, followed by every 5 seconds for

approximately 1 hour (0’05); every second for the fi rst 3 minutes, followed by every 2 minutes for
approximately 12 hours (2’00)

Altitude Records:

Up to 40 records (shared storage with date/time, bearing, and barometric pressure/temperature

records)

Historical Altitude Values: 1 record of high altitude, low altitude, cumulative ascent, cumulative

descent

Other: Reference altitude setting; Altitude differential; Altitude auto reading interval (0’05 or 2’00) ;

Altitude Differential Graph

Digital Compass: 60 seconds continuous reading; 16 directions; Angle value 0° to 359°; Four direction

pointers; Calibration (2-point); Magnetic declination correction; Bearing Memory; Bearing Records:
Up to 40 records (shared storage with date/time, altitude, and barometric pressure/temperature
records)

Barometer:

Measurement and display range:

260 to 1,100 hPa (or 7.65 to 32.45 inHg)

Display unit: 1 hPa (or 0.05 inHg)
Reading timing: Daily from midnight, at two hour intervals (12 times per day); Every fi ve seconds in

the Barometer/Thermometer Mode

Barometric Pressure/Temperature Records: Up to 40 records (shared storage with date/time, altitude,

and bearing records)

Other: Calibration; Manual reading (button operation); Barometric pressure graph; Barometric

pressure differential pointer; Barometric pressure change indicator

E-102

Thermometer:

Measurement and display range: –10.0 to 60.0°C (or 14.0 to 140.0°F)
Display unit: 0.1°C (or 0.2°F)
Reading timing: Every fi ve seconds in the Barometer/Thermometer Mode
Other: Calibration; Manual reading (button operation)

Temperature Sensor Precision:

±2°C (±3.6°F) in range of –10°C to 60°C (14.0°F to 140.0°F)

Bearing Sensor Precision:

Direction: Within ±10°

Values are guaranteed for a temperature range of –10°C to 60°C (14°F to 140°F).

North pointer: Within ±2 digital segments

Pressure Sensor Precision:

Measurement accuracy: Within ±3hPa (0.1 inHg) (Altimeter accuracy: Within ± 75m (246 ft.))

Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).

Precision is lessened by strong impact to either the watch or the sensor, and by temperature

extremes.

World Time: 48 cities (31 time zones)

Other: Daylight Saving Time/Standard Time

Stopwatch:

Measuring unit: 1/100 second
Measuring capacity: 999:59' 59.99"
Measuring accuracy: ±0.0006%
Measuring modes: Elapsed time, split time, two fi nishes

E-103

Countdown Timer:

Measuring unit: 1 second
Countdown range: 24 hours
Setting unit: 1 minute

Alarms: 5 Daily alarms (four one-time alarms; one snooze alarm); Hourly time signal
Sunrise/sunset:

Sunrise/sunset time display; selectable date

Illumination: LED light; Selectable illumination duration (approximately 1.5 seconds or 3 seconds); Auto

Light Switch (Full Auto Light operates only in the dark)

Other: Battery power indicator; Power Saving; Low-temperature resistance (–10°C/14°F); Button

operation tone on/off

Power Supply: Solar panel and one rechargeable battery

Approximate battery operating time: 7 months (from full charge to Level 4) under the following

conditions:

Light: 1.5 seconds/day

Beeper: 10 seconds/day

Direction readings: 20 times/month

Climbs: Once (approximately 1 hour of altitude readings)/month

Barometric pressure change indicator readings: Approximately 24 hours/month

Barometric pressure graph: Readings every 2 hours

Time calibration signal receive: 4 minutes/day

Display: 18 hours/day

Frequent use of illumination runs down the battery. Particular care is required when using the auto
light switch (page E-91).

Operation Guide 3410

Advertising
This manual is related to the following products: