PXL-250 Tiger Controller

1530 Old Oakland Road, Suite 100

01835-002 Rev. 4.2

San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]

Page 9 of 25

PXL-250

Quick Start Guide

4.5

Connecting a Door Status Input

Each PXL-250 is shipped with an installation kit including all necessary terminal blocks and transorbs. One of these
terminal blocks has a jumper across pins 1 and 2. This terminal block is designated for use on TB-4. If a door switch is
not used on the controller, this jumper prevents a continuous door open status alarm from being received by the
controller. If a door switch is used, simply remove this jumper and install the door switch leads.

Figure 7: Door Status Input Connections

NOTE: A Door Switch must be installed on any door to which anti-passback is being applied for proper tracking of the
anti-passback feature in the Doors program.

4.6

Connecting a Request to Exit (RTE) Input

Figure 8: Request to Exit Input Connections