2 wiring to a dry contact device, Irp-1 isolation relay, Installation guide – Keri Systems IRP-1 User Manual

Page 3

Advertising
background image

IRP-1 Isolation Relay

Installation Guide

Page 3 of 4

P/N: 01833-001 Rev. H

4.2

Wiring to a Dry Contact Device

N/O

N/C

COM

– +

IRP-1

+

12 VDC

Controller Power Supply

Keri Controller

Connection for a

Fail-Safe Device

Connection for a

Fail-Secure Device

Controller Power

Ground

NO / Lock

Common

NC / Lock

Other Pins

Relay Terminal Block

Power Terminal Block

Dry

Contact

Device

Transorb