Telebyte 209 Short Haul Modem

2305 Bering Drive

01850-001 Rev. G

San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: [email protected]

Page 2 of 5

Quick S

tart Guide

Short Haul Modem

2.1

Connecting to a PXL-250 Controller

The DB-9 connector on the short haul modem and on the PXL-250 controller are both female. To
make the short haul modem to controller connection a DB-9 male-to-male connector is provided
(see Figure 1). Set the switch on the short haul modem to the DCE position by gently turning the
switch completely counter-clockwise.

Figure 1: PXL-250 Controller to Short Haul Modem Connection

2.2

Connecting to an EntraGuard Gold Controller

A short haul modem may be used with an EntraGuard Gold master controller however, due to the
size of the short haul modem, an extension cable must be made to allow the modem to be located
outside of the controller box so the box may close properly.

The DB-9 connector on the short haul modem and on the EntraGuard Gold controller are both
female. To make the short haul modem to controller connection two DB-9 male connectors are
required and a minimum of 3 conductor cable (length as needed). Set the switch on the short haul
modem to the DCE position by gently turning the switch completely counter-clockwise.

Figure 2: EntraGuard Gold Controller to Short Haul Modem Connection