EntraGuard

®

Gold Telephone Entry Controller

1530 Old Oakland Road, Suite 100

01801-001 Rev. 2.2

San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]

Page 28 of 32

Quick S

tart Guide

EntraGuard

®

– Gold

7.0

Powering the Controller for the First Time

NOTE: Verify the earth ground has been connected at pin 3 of TB-2 before turning the power on for the first time.

7.1

Verify the 12 VDC Supply Voltage

To verify the 12 VDC supply voltage:

1. Turn system power on.
2. Set the DVM to a DC volt scale capable of reading 12 VDC.
3. Place the Red DVM lead on Pin 1 of TB-2.
4. Place the Black DVM lead on Pin 2 of TB-2.
5. Check the DVM reading. It should read +12 VDC +/- 2 volts.

If the DVM does not read 12 VDC, verify the power supply is of the correct voltage, verify the cable length does not
exceed 200 feet, and verify the cable gauge is AWG 18.

NOTE: On long power cable runs, keep in mind the resistance in the cable itself causes a drop in voltage at the end of
the run. The power supply must be able to account for this voltage drop.

8.0

Setup Controller

If you're turning system power on for the first time, certain tasks must be performed prior to entering access control
information from Doors. On the EntraGuard Gold main board (see Figure 3 on page 3), hold the S1 Button down and
turn the controller’s power on. After the controller beeps once, indicating the controller’s firmware is ready for
programming, release the S1 button. The LCD on the front panel will display the Reset Menu (see Figure 34). From this
menu you may perform different tasks such as set the controller’s address, clear the controller’s memory, set the
microphone gain, and check diagnostics.

Figure 34: Reset Menu

NOTE: If no keys have been selected within 60 seconds, the unit will time out and go directly to the default message. In
order to reach the Reset Menu, the unit must be powered up again.