Keri Systems MR51e User Manual

Mr51e reader interface, General, Mr51e hardware

Advertising
background image

Mercury Security © 2013

MR51e

DOC 10107-0035

REV 1.05

Page 1

www.mercury-security.com

2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562)986-9105 FAX (562) 986-9205

This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.

MR51e Reader Interface

Installation and Specifications

1. General:

The MR51e reader interface provides a network connected, single door with paired reader, PoE based
solution to the OEM integrator for interfacing TTL/Wiegand/RS-485 type readers to door hardware. The
on-board twisted pair Ethernet jack with PoE support enables easy installation.

Note: For UL, the Power Sourcing Equipment (PSE) such as a PoE enabled network switch and/or PoE
power injectors must be UL Listed under UL294.

One physical barrier can be controlled with the MR51e, using single or paired readers. The first reader
port can accommodate a read head that utilizes Wiegand, magnetic stripe, or 2-wire RS-485 electrical
signaling standards, one or two wire LED controls, and buzzer control (one wire LED mode only).

The second reader port can accommodate a read head that utilizes Wiegand or magnetic stripe
signaling, one or two wire LED controls, and buzzer control (one wire LED mode only). Two Form-C
relay outputs may be used for door strike control or alarm signaling. The relay contacts are rated at 5 A
@ 30 Vac/dc, dry contact configuration. Four inputs are provided for monitoring the door contacts, exit
push buttons, and alarm contacts. The MR51e requires power from PoE or local 12 Vdc. The MR51e
may be mounted in a 3-gang switch box; a mounting plate is supplied with the unit. The MR51e may be
mounted in an enclosure; the supplied mounting plate has mounting holes that match the MR50
mounting footprint.

2. MR51e Hardware:

2

3

4

1

S1

S2

1

2

3

4

5

6

ON

J3
J7

K1

K2

12V

J5

PoE

J6

TB1

TB2

TB3

TB4

TB5

TB6

1

1

1

1

1

1

IN1

IN2

IN3

IN4

VO LED BZR CLK DAT GND

VO GND

DAT

CLK

BZR

LED

GND

VIN

NO

NC

2-C

NO

NC

1-C

J2

0.

2 [5.0

8]

2.

35 [59.

69]

0.15 [3.81]

2.55 [64.77]

2.55 [64.77]

5.4 [137.16]

STATUS LEDs

2.

75 [69.

85]

DIP SWITCH

RESET SWITCH

PoE/12Vdc
POWER SELECTOR

JUMPER

ETHERNET RJ45

CONNECTOR

ACTIVITY

(YELLOW)

LINK
(GRREN)

Ш0.125 [Ш3.18]

4 PLACES

1 2 3 4 5 6

VO

VO

IN2

IN1

IN3

IN4

LED

BZR

CLK

DAT

GND

LED

BZR

CLK

DAT

NC

GND

GND

VI

N

NO

RLY 1

NO

RLY 2

NC C

C

TB6

TB5

TB4

TB3

TB2

TB1

J1

6V

5V

3.3V

LNK

ACT

(K1)

(K2)

J4

D24

D19

ETHERNET

STATUS

LEDs

RELAY K1

LED

RELAY K2

LED

STATUS LEDs

SOLDER SIDE

Advertising