3 configure input property sets, 4 configure output property sets – Keri Systems Doors NetXtreme User Manual

Page 31

Advertising
background image

Figure 24: Input Property Sets

Figure 25: Output Property Sets

Keri Systems, Inc.

Doors NetXtreme

TM

Reference Manual

01945-100 Rev. 4.0

Page 29

9.1.3

Configure Input Property Sets

Click on Setup > System > Properties (tab) > Inputs.

1. Click “Add New” button or “Duplicate” button.
2. Rename the Property set name.
3. Set Input Mode: Not Used, Normally Open, Normally Closed.
4. Set Supervision: None (2 State), 3 State, 4 State.
5. Set Monitor Timezone: Always, Never, created timezones.
6. Apply Changes or Undo Changes.

9.1.4

Configure Output Property Sets

Click on Setup > System > Properties (tab) > Outputs.

1. Click on the “Add New” button or “Duplicate” button.
2. Rename the Property set name.
3. Set Normal Output State: Not Used, Energized, Deenergized.
4. Set Active Time: Supervision: anywhere between Always and 86,400 seconds (1,440 minutes or 24

hours).

5. Set Output Use: General or Elevator.
6. Apply Changes or Undo Changes.