0 wiring an elevator control system, Doors32 ™ elevator control – Keri Systems Doors32 Elevator Control User Manual

Page 2

Advertising
background image

Doors32™ Elevator Control

2305 Bering Drive 01878-001 Rev. E

San Jose, CA 951

31 USA

(800) 260-5265 (408) 4

35-8400 FAX (408) 577-1792

Web: www.kerisys.com E-mail: [email protected]

Page 2 of 4

Application Note

Doors32

2.0

Wiring an Elevator Control System

For elevator control there are four reader to PXL-250 controller wiring connections that must be
made. Figure 1 provides a wiring diagram of an elevator control system.

1. The reader antenna line must be daisy-chained to all controller antenna inputs (Pin 1 of TB-5 or

TB-6 on the controllers).

2. The reader ground line must be daisy-chained to all controller antenna grounds to provide a

standard ground reference for all controllers (Pin 4 of TB-5 or TB-6 on the controllers).

3. The reader shield line must be connected to the A-door controller antenna ground at the master

controller (Pin 4 of TB-5 on the master controller).

4. The power line must be connected to the master controller only (Pin 3 of TB-5 on the master

controller).

Advertising