Model 380, Tedea-huntleigh, Co-planar beam load cell – KERN & SOHN MXS 300K100M Addendum User Manual

Page 2: Specifications

Advertising
background image

Tedea-Huntleigh

www.vpgtransducers.com

2

Model 380

Technical contact in Americas: [email protected];

Europe: [email protected]; Asia: [email protected]

Document No.: 12075

Revision: 26-Jul-2012

Co-Planar Beam Load Cell

SPECIFICATIONS

PARAMETER

VALUE

UNIT

Rated capacity—R.C. (E

max

)

7.5, 37.5, 50, 75, 150, 250

kg

TH accuracy class

E

G4

H5

OIML Accuracy class

NA

C3

C4

Maximum no. of intervals (n)

NA

3000

4000

Y = E

max

/V

min

*

NA

7500*

7500*

Rated output—R.O.

1.0

mV/V

Rated output tolerance

0.10

0.001

±mV/V

Zero balance

0.10

±mV/V

Creep, 30 min.

0.074

0.024

0.018

±% of load

Zero return, 30 min.

0.05

0.0167

0.0125

±% of load

Temperature effect on output

0.002

0.001

0.00075

±% of load/°C

Temperature effect on zero

0.007

0.00186

0.00186

±% of R.O./°C

Input impedance

1160±15

Ω

Output impedance

1000±10

Ω

Insulation resistance

5000

Temperature range, compensated

–10 to +40

°C

Temperature range, safe

–30 to +70

°C

Maximum safe central overload

300

% of R.C.

Ultimate static overload

400

% of R.C.

Safe side load

200

% of R.C.

Cable type

4 conductors, 26AWG, flat, PVC

Cable length

1.5

m

Color code

+Exc: Green, +Sig: Red, -Exc: blk, -Sig: wht

Construction

Aluminum, RTV potting

Environmental protection

IP65

Outline dimensions drawing

378.000.003

* Consult factory for higher Y values availability
All specifications subject to change without notice.

Wiring Schematic Diagram

+ve Input (Green)

–ve Input (Black)

+ve Output (Red)

–ve Output (White)

The load cell is provided with a 4 conductor ribbon

cable and with optional AMP#103957-4 connector

4

1

2

5

Advertising