Instruction Manual

TC_car

TC_car-BA-e-1110

2

3-4 Battery compartment/ cover
3-5 Jack for RS-232C interface
4. Measuring procedure

4.1 The Power- on/Power-off key 3-3 is to be pressed to
switch on the instrument.`0`appears on the display 3-2.

The instrument recognizes the sensor itself,by the

symbol `Fe` (= F) or `NFe` (= N) which is indicated
on the display. The instrument enters the auto mode
which can automatically recognize the base plate.

4.2 The sensor 3-1 is to be placed onto a coating layer to
be measured. The reading on the display is the thick-
ness of the coating layer.
4.3 For the next measurement the sensor 3-1 is to be
lifted for more than 1cm and step 4.2 is to be
repeated.
4.4 In case of inaccuracies to the measurement result it is
recommended to calibrate the instrument before

measuring as described in part 5.

4.5 The instrument can be switched off by pressing the
Power- on/ Power- off key 3-3. The power will switch
itself off 50 seconds after the last operation.
4.6 The measurement unit can be indicated with `µm` or
`mil`. To convert:
The Zero/ Power- on/ off key 3-3 has to be pressed
and not to be released until `UNIT` appears on the
display. The measurement unit changes by releasing.
All in all this operation lasts about 6 seconds (from
starting pressing the Zero-/ Power-on/ off key).
4.7 To change the measuring mode from `single` to `con-
tinuous or vice visa, the Zero/ Power- key 3-3
is to be pressed and not released until `SC` appears
on the display. The measuring mode changes into
the other one when the key is released. This lasts
about 8 seconds. The symbol ((•)) on the display
indicates the continuous mode.

5. Calibration

5.1 Zero adjustment:
Zero adjustment for `Fe` (=F) and `NFe` (=NF) should
be carried out separately.
The iron base plate is to be used if `Fe` is
shown on the display. The base plate of aluminium is
to be used if `NFe` is shown on the display.
The sensor 3-1 is to be placed carefully onto the base
plate and the Zero-/ Power key is to be pressed without
lifting the sensor. `0` appears on the display.
Attention: The calibration is invalid if the sensor is
not directly placed on the base plate or another un-
coated material.

6. Battery replacement

6.1 If the battery symbol ``+/-`` appears on the display, the
batteries should be replaced.
6.2 The battery cover 3-4 is to be removed and the
batteries are to be taken off.
6.3 The batteries (4x1.5V AAA/UM-4) are to be installed

correctly into the case.
6.4 If the instrument is not to be used for an extended
period, batteries are to be extracted.
7. Calibration foils

As accessory there is included a foil set of different foils
and ranges, which is to be seen below.

STANDARD FOIL INCLUDED

Range
(µm)

CM
25

CM
50

CM
100

CM
200

CM
500

CM
1000

0-200

X

X X

X

0-500

X

X

X

X

0-
1000

X X

X

X

X

0-
2000

X

X

X X

X

8. Trouble shooting

8.1 The instrument should always be calibrated on the
uncoated base material to be measured instead of the
base plate included in the delivery. Then the
accuracy is more precise.
8.2 Sensors will eventually wear off. Life of the sensor will
depend on the number of measurements taken and
how abrasive the coating is.

9. Declaration of conformity