Warning – LAARS EverHot (interior) Venting Components - Installation Manual User Manual
Page 2
2
WARNING
All joints in the vent/air intake piping must be taped with aluminum tape at the completion of the venting
system installation to prevent any possible leakage into the room.
Make sure all the pipe connections are firmly pressed together so that the gaskets form a tight seal.
Condensate
When the total vent system length is greater than 5 ft. (1,52 m), condensate will form which could
damage the water heater. For vent lengths greater than 5 ft. (1,52 m), a condensate collector and
trap must be installed.
Recommended vent/air intake terminal position
Terminals should be so positioned as to avoid products of combustion entering openings into buildings or
other flues or vents.
Figure 12
WARNING
Before installation inspect each vent component for damage and correct seal placement. Do not attempt to
fix or install any damaged vent components.