Endurance User's Information

Page 5

SECTION 1.
Caring For Your Endurance

Your Endurance will require very little

maintenance. However, as with any fine appliance,

there are certain steps you should take to insure

continuing optimum performance.

1A. General Care

Keep your Endurance area clear and free from

combustible materials, gasoline and other flammable

vapors and liquids.

If you desire, clean the jacket surfaces with a

damp cloth and mild soap. Do not use flammable

cleaning materials.

Keep vent terminal free of obstructions. Do not

pile snow against vent terminal.

1B. Annual Inspection of Flues and Vents

You should visually inspect the vent pipe once a

year. Should any corrosion exist, have the affected

parts replaced.

On horizontally vented units installed with

p/n 2400-009 (Direct Vent Kit) inspect the metal vent

terminal (see Figure 3) on the outside of the building

for corrosion. Replace if necessary.

On all models installed without the Direct Vent

Kit, clean and inspect the condensate collection and

disposal system which is a part of the flue assembly.

1C. Shutting Down the Endurance

The need may arise to shut down your Endurance

(extended stay away from home, for example). If so,

the following steps are required:

1.

Switch off main disconnect switch (located on

back of control panel).

2.

Close gas shutoff valve above combination gas

control valve (inside unit).

3.

Close main manual gas valve.

4.

If freezing is anticipated, drain Endurance and

be sure to protect building piping from

freezing, also.
The above steps may require qualified service

personnel.

1D. To Restart Endurance

Should the need arise (power interruption, for

example), you may have to restart your Endurance.

Follow these steps:

1.

Depress the reset button on the top of the control

panel for at least one second, and then release.

2.

Turn up thermostat to call for heat.

3.

In approximately 2 seconds, the blower will

operate and ignition should occur after 35-40

seconds. It may take as long as 2½ minutes.

4.

If ignition does not occur, wait 5 minutes and

then repeat steps 1 through 3.

5.

If, after three attempts, you still are unable to

achieve ignition, shut down the boiler and call

your service technician.

If drained, follow these steps:

1.

Follow “Installation Manual” for proper filling

and purging.

2.

Turn on main manual gas valve.

3.

Remove front door and turn on gas shutoff valve,

above combination gas control valve.

4.

Switch on main disconnect switch, depress on/

off button on front of control panel, and depress

black reset button on top of control panel (pump

and blower will start and igniter will be

energized, after 35 seconds the gas valve will be

energized, and ignition will occur). If ignition

does not occur within 2½ minutes switch “off”

main disconnect switch, wait 5 minutes and

switch “on” again. If after three attempts ignition

does not occur, initiate shutdown procedure and

call for service.

1E. In the Event of Power Failure

The Endurance cannot be operated during an

electrical power outage. If there is an extended power

outage with danger of freezing, then the Endurance

(and all other water systems) should be completely

drained. When draining the unit, turn off gas and turn

off the main power switch. When replacing in service,

refer to start-up instruction for proper filling and

purging.

1F. Full Service Every 3 Years

In addition to the annual visual inspections by

the homeowner, a qualified service agency should

conduct a detailed inspection of all flue product

carrying areas of the boiler and vent system. This

should be done in accordance with the service

instruction in the “Installation and Operating

Instructions Manual” for the Endurance.

Caution

Do not use this boiler if any part has been under
water. Immediately call a qualified service
technician to inspect the boiler and to replace any
part of the control system and any gas control
which has been under water.

WARNING

Should overheating occur or the gas supply fail to
shut off, do not turn off or disconnect the electrical
supply to the pump. Instead, shut off the gas supply
at a location external to the Endurance.
En cas de surchauffe ou si l’admission de gaz ne
peut être coupée, ne pas couper ni débrancher
l’alimentation électrique de la pompe. Fermer plutôt
le robinet d’admission de gaz à l’extérieur de
l’appareil.