SECTION 1.

Caring For Your Mighty Therm2

Your Mighty Therm2 will require very little

Maintenance. However, as with any fine appliance

there are certain steps that should be taken to ensure

continuing optimum performance.

1.1 General Care

Keep the area around the Mighty Therm2 clean

and free from combustible materials, gasoline and

other flammable liquids and vapors.

The Mighty Therm2 must be completely isolated

and protected from any source of corrosive chemical

fumes such as trichlorethylene, perchlorethylene,

chlorine, etc.

Keep grille openings on the boiler free for proper

ventilation of interior components.

Do not obstruct or block a free flow of air to the

boiler to ensure proper ventilation.

If desired, clean the jacket surfaces with a damp

cloth and mild detergent. Do not use flammable

cleaning materials.

If sidewall vented, keep the vent terminal clear

of obstructions — do not pile snow against the vent

terminal. Clean the air filter(s) often, and then develop

an appropriate maintenance schedule.

1.2 Annual Inspection of Flue and Vents

Visually inspect the vent pipe once a year. Should

any deterioration exist, have the affected parts replaced

by a qualified service person.

1.3 Shutting Down the Mighty Therm2

1. Switch off the main electrical disconnect switch.

2. Close all manual gas valves.

3. If freezing is anticipated, drain the Mighty

Therm2 and be sure to also protect the building

piping from freezing. This step to be performed

by a qualified service person.

1.4 To Restart the Mighty Therm2

If drained, follow the Installation and

Operation Manual for proper filling and purging.

1. Switch off the main electrical disconnect switch.

2. Close all manual gas valves.

3. WAIT FIVE (5) MINUTES.

4. Set the aquastat or thermostat to its lowest

setting.

5. Open all manual gas valves.

6. Reset all safety switches (low water cut off,

manual reset high limit, etc.).

7. Set the temperature controller to the desired

temperature setting and switch on electrical

power.

8. Burner will go through a prepurge period and

ignitor warm-up period, followed by ignition.

1.5 In the Event of a Power Failure

The Mighty Therm2 can not be operated during

an electrical power outage. If there is an extended

power outage with danger from freezing, then the

Mighty Therm2 (and all other water systems) should

be drained completely. When draining the boiler, turn

off main electrical disconnect switch. When placing

back in service, refer to start-up instructions in the

Installation and Operation Manual for filling and

purging. Draining and filling shall only be done by a

qualified service person.

1.6 Full Service Every Three (3) Years

In addition to the annual visual inspections, a

qualified service agency should conduct a detailed

inspection of all flue product carrying areas of the

boiler and its venting system.

WARNING

Do not use this boiler if any part has been

under water. Immediately call a qualified

service technician to inspect the boiler and to

replace any part of the control system and any

gas control which has been under water.

WARNING

Should overheating occur or the gas supply

fail to shut off, do not turn off or disconnect the

electrical supply to the pump. Instead, shut

off the gas supply at a location external to the

boiler.

FOR SERVICE

Contact your installing contractor, gas utility,

Laars dealer, or call Laars for the nearest

authorized representative in your area.