Laars heating systems – LAARS Mini-Combo id MCH - Install and Operating Manual User Manual

Page 4

Advertising
background image

Page 4

LAARS Heating Systems

Boiler

Space Heating -

Refer to Document 1080

Tank

Figure 3. Piping Schematic.

Cold

Water

Supply

Hot

Water

Supply

Figure 4. Typical Expansion Tank Installation.

Figure 2. Dimensional Information.

Dimensions inches

mm

Size

A

50

14

356

75

15

381

100

16

406

125

17

432

Boiler In/Out NPT

(all sizes)

Gas NPT (all sizes)

½*

Domestic Hot Water (all sizes)
Inlet/Outlet NPT

¾

Minimum clearances from

combustible surfaces:

Left Side: 2" 51mm

Right Side: 2" 51mm

Rear: 2" 51mm

Front: 4" 102mm Top: 23" 584mm

Service clearances:

Allow 4" 102mm on each side

for piping access.

*¾" for model 125 Natural.

60

(1521)

28

(711)

41.5

(1054)

32.5

(826)

7

(178)

24

(610)

24

(610)

.75

(19)

62.5

(1588)

Domestic

Hot Water

Outlet

Cold Water

Inlet

Side View

Front View

Check Valve

Tank

Pump

Boiler Flue Collar 4 (102)

Dimensions shown
in inches (mm).

7

(178)

24

(610)

Tank

Aquastat

Drain

Valve

Tank

Relief
Valve

Advertising