General information and installation – LABEC B-IM0120FSCW User Manual

Page 3

Advertising
background image

8.

See data plate on the rear side of the unit

and check that local main voltage corresponds

with the voltage specified on it.

CAUTION. Incorrect voltage supplied to
the icemaker will void your parts
replacement program.

9.

Remove the manufacturer’s registration card

from the inside of the User Manual and fill-in all

parts including: Model and Serial Number taken

from the data plate.

Forward the completed self-addressed

registration card to SIMAG factory.

C.

LOCATION AND LEVELLING

WARNING. This Modular Flaker and
Superflaker is designed for indoor
installation only. Extended periods of
operation at temperature exceeding the
following limitations will constitute misuse
under the terms of the SIMAG
Manufacturer’s Limited Warranty resulting
in LOSS of warranty coverage.

1.

Position the storage bin in the selected

permanent location.

Criteria for selection of location include:

a) Minimum room temperature 10°C (50°F)

and maximum room temperature 40°C (100°F).

b) Water inlet temperatures: minimum 5°C

(40°F) and maximum 40°C (100°F).

c) Well ventilated location for air cooled

models (clean the air cooled condenser at frequent

intervals).

d) Service access: adequate space must be

left for all service connections through the rear of

the ice maker. A minimum clearance of 15 cm (6")

must be left at the sides of the unit for routing

cooling air drawn into and exhausted out of the

compartment to maintain proper condensing

operation of air cooled models.

2.

Level the icemaker in both the left to right

and front to rear directions by means of the

adjustable legs.

D.

ELECTRICAL CONNECTIONS

See data plate for current requirements to

determine wire size to be used for electrical

connections. All SIMAG icemakers require a

solid earth wire.

All SIMAG ice machines are supplied from the

factory completely pre-wired and require only

electrical power connections to the wire cord

provided at the rear of the unit.

GENERAL INFORMATION
AND INSTALLATION

A.

INTRODUCTION

This manual provides the specifications and the

step-by-step procedures for the installation, start-

up and operation, maintenance and cleaning for

the SIMAG SPR 80, SPR 120 and SPR 165

Icemakers.

The Electronic Flakers are quality designed,

engineered and manufactured.

Their ice making systems are thoroughly tested

providing the utmost in flexibility to fit the needs

of a particular user.

NOTE. To retain the safety and performance

built into this icemaker, it is important that

installation and maintenance be conducted

in the manner outlined in this manual.

B.

UNPACKING AND INSPECTION

1.

Call your authorized SIMAG Distributor or

Dealer for proper installation.

2.

Visually inspect the exterior of the packing

and skid. Any severe damage noted should be

reported to the delivering carrier and a concealed

damage claim form filled in subjet to inspection of

the contents with the carrier’s representative

present.

NOTE. If there are doubts, on the delivery

note register the following caption:

ACCEPTED WITH RESERVATION.

3.

a) Cut and remove the plastic strip securing

the carton box to the skid.

b) Remove the packing nails securing the

carton box to the skid.

c) Cut open the top of the carton and remove

the protection sheet.

d) Pull out the polystyre posts from the

corners and then remove the carton.

4.

Remove the front panel of the unit and

inspect for any concealed damage. Notify carrier

of your claim for the concealed damage as stated

in step 2 above.

5.

Remove all internal support packing and

masking tape.

6.

Check that refrigerant lines do not rub

against or touch other lines or surfaces, and that

the fan blades move freely.

7.

Check that the compressor fits snugly onto

all its mounting pads.

Page 1