To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
• Install door control within sight of garage door, out of reach

of children at a minimum height of 5 feet (1.5 m), and away
from ALL moving parts of door.

• NEVER permit children to operate or play with door control

push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is properly

adjusted and there are no obstructions to door travel.

• ALWAYS keep garage door in sight until completely closed.

NEVER permit anyone to cross path of closing garage door.

INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of door at a minimum
height of 5 feet (1.5 m) where small children cannot reach,
and away from all moving parts of door and door
hardware.

1. Strip 1/4" (6 mm) of insulation from one end of the bell

wire. Connect it to the two screw terminals on the back
of the door control by color: white wire to 2 and
white/red wire to 1.

2. Fasten the Lighted Door Control Button securely with

6ABx1-1/2" screws. If installing into drywall, drill 5/32"
holes and use the anchors provided.

3. Run the bell wire up the wall and across the ceiling to

the opener. Use insulated staples to secure the wire in
several places. Be careful not to pierce the wire with a
staple, creating a short or open circuit.

4. Receiver terminal screws and the antenna are located

on the back panel of the motor unit. Position the
antenna wire as shown.

5. Then connect the bell wire to the opener terminal

screws: white to 2 and white/red to 1.

6. Use tacks or staples to permanently attach the

entrapment warning label to the wall near the door
control, and the manual release/safety reverse test in a
prominent location on the inside of the garage door.

NOTE: DO NOT connect the power and operate the
opener at this time. The trolley will travel to the full open
position, but will not return to the close position until the
sensor beam is connected and properly aligned.

Drywall Anchors

Insulated
Staples

Screw 6ABx1-1/2"
Lighted Door Control Button

HARDWARE SHOWN ACTUAL SIZE

Opener
Terminal Screws

Bell Wire

Antenna

Back Panel

Lighted Door
Control Button
Terminal Screws

Bell Wire

WHT

RED

Kg

1

3

9

7

5

1

3

9

7

5

2

3

1

-2

-1

Lighted
Door Control Button

Kg

Advertising