Schwintek in-wall™ troubleshooting guide – Lippert Components Schwintek In Wall Slide-Out System User Manual

Page 9

Advertising
background image

Rev: 01.30.2015

Page 9

Lippert In-Wall Troubleshooting Guide

Gear Rack

Visual Inspections
Measurements

1. Measure from the outside edge of the column to the face of the gear rack (Fig. 13 and 14). The

standard measurement should be 2

1/2

" plus or minus

1/8

". Take this measurement when the room is

fully extended and again when the room is 3" from fully retracted.

NOTE: For units with non-standard installations, contact the OEM for their specific measurements.
2. Measure the gear racks for parallel. There should be less than

1/8

" difference between the parallel

measurements.

3. Check for proper seal engagement (no binding).
4. Check for damage to gear rack.

Fig. 13 - Gear Rack Measurements

Fig. 14 - Column and Gear Rack

Column

Column

Gear Rack

2.5" +/- .125"

(Standard)

SCHWINTEK IN-WALL™ TROUBLESHOOTING GUIDE