PHONOGENE Panel Controls

1. Signal IN Rotary Level Control: For Line Level set at 70% CW, and for 10Vpp at set

30% CW. Faceplate is marked accordingly.

2. Signal IN: Line Level or typical Modular Synth levels acceptable. AC Coupled.

3. Sound On Sound CV IN: sets mix of previously recorded Loop with Live Signal input

when recording, to allow for Sound on Sound type “overdubs.” Also allows for

setting monitoring level of Live input signals with previously recorded Loop. May be

misused as a Voltage Controlled Crossfader (between Live and Loop) or VCA for \

Loop (no Live Signal). Range 0V to 10V, linear response. Normalized to +10V.

4. Sound On Sound Attenuator: with nothing patched to SOS CV IN (which is normalized

to +10V) works as standard panel control. With Signal Patched to SOS CV IN,

works as attenuator for that signal.

5. Signal OUT: 10Vpp (depending upon Signal IN attenuator setting and source material),

AC coupled.

6 & 7. VARI-SPEED and Splice Indicator LEDs: These LEDs tell user in which direction

the Phonogene is playing. The LEFT Blue (7) LED indicates reverse playback,

right Orange LED (6) indicates forward playback. When no LEDs are lighted,

playback is stopped.

1

3

5

5

7

9

16 17 18

2

6

7

8

9

10

11

12

13

14 15

19 20 21

28

27

26

25

24

23

22

4

Advertising