Maxim Integrated 6612_OMU_S2_URT_V1_13 User Manual

Page 22

Advertising
background image

6612_OMU_S2_URT_V1_13 Firmware Description Document

FDD_6612_010

22

Rev. 1.1

Output

Location

(hex)

LSB

Comment

Example

Bit 14 – MAXIB_WB

maximum

wideband current exceeded on

Outlet 2.

Bit 15 – PFB_NB negative –

Narrowband Power Factor Negative

Threshold Alarm for Outlet 2.

Bit 16 – PFB_NB positive

Narrowband Power Factor Positive

Threshold Alarm for Outlet 2.

Bit 17 – PFB_WB negative

Wideband Power Factor Negative

Threshold Alarm for Outlet 2.

Bit 18– PFB_WB positive

Wideband Power Factor Positive

Threshold Alarm for Outlet 2.

Bit 19 – MAXIT_WB

maximum

total wideband current exceeded on

both Outlet 1 and Outlet 2.

Bit 20 – MAXIT_NB

maximum

total narrowband current exceeded

on both Outlet 1 and Outlet 2.

Bit 21 – CREEP A Alert – Creep

Alert on Outlet 1.

Bit 22 – CREEP B Alert – Creep

Alert on Outlet 2.

Bit 23 – Line/Neutral Reversal

detected.

Bit 24 – Reserved.
Bit 25 – Reserved.

Bit 26 – Unexpected Reset.

Bits 27-31 – Reserved.

Note: Duplicate of address 0x02

(see

Table 2

)

Irms_wb A

Overcurrent

Event Count

23

Counter increments on each edge

event.

If four wideband over current

events have occurred on Outlet 1:

)23?<CR>

Returns: +4

Vrms Under

Voltage

Event Count

24

Counter increments on each edge

event.

Note: Duplicate of address 0x04

(see

Table 2

).

If four under voltage events have

occurred:

)24?<CR>

Returns: +4

Vrms Over

Voltage

Event Count

25

Counter increments on each edge

event.

Note: Duplicate of address 0x06

(see

Table 2

).

If four over voltage events have

occurred:

)25?<CR>

Returns: +4

Vrms A

26

mV

Vrms voltage

Note: Duplicate of address 0x06

(see

Table 2

).

If the line voltage is 120 V

)26?<CR>

Returns:

+120.000

Watts A

27

mW

Outlet 1 active power

measurement (per second).

Note: Duplicate of address 0x07

(see

Table 2

).

If 120 W atts are measured on

Outlet 1

)27?<CR>

Returns:

+120.000

Advertising