71M6541 Demo Board REV 3.0 User’s Manual

27

Rev 4.0

i_max2

4

Like i_max, except
for the 2nd current
sensor.
Currents, Wh etc.
using currents from
the second sensor
are rescaled into the
same units as the
first current sensor.

0.1 Amps

208 A (2080)

)1C

signed

16

in_limit

3

Maximum valid neu-
tral current.

Same units as CE’s i3sqsum.

0.1A

)1D

signed

32

in_wait

3

The time that neu-
tral current can ex-
ceed n_max before
the neutral error is
asserted.

Count of accumulation intervals.

10 secs.

)1E

signed

16

Reserved

)1F

meter_id

8

Identification num-
ber of meter.

32 bit unsigned number. For
AMR demonstrations, this is
sent in decimal as the identifica-
tion number of the meter.

100000000

)20

signed

32

temp_datum

8

Count of tempera-
ture sensor at cali-
bration.

Refer to the IC data sheet.
Temperature is calculated as
temp = (measured_temp –
temp_datum)/temp_cal1 +
temp_cal0

n/a

)21

signed

32

mtr_datum[0.
.3]

8

Center temperature
of a meter element’s
temperature curve.

0.1C

22C

)22..

25

signed

16

rtca_adj

8

Default value for
RTCA_ADJ, the
crystal’s capacitor
adjustment.

Refer to the IC data sheet. Set
from hardware value when
hardware is changed.

Hardware de-
fault (refer to
the IC data
sheet).

)26

unsigned

8

y_cal0 5,

8

RTC offset rate ad-
just

100ppb

0

)27

signed

16

v_bat_min

8

Minimum valid bat-
tery voltage.

Units of hardware’s battery
measurement register.

2V on a real
PCB; should be
adjusted for
battery and
chip.

)28

signed

32

cal_cnt

Count of calibra-
tions. In demo code,
it also checks ad-
justments.

Counts number of times calibra-
tion is saved, to a maximum of
255.

0

)29

unsigned

8

ver_hash

Checked to prevent
old calibration data
from being used by
new code. Value
that changes with
the banner text, and
therefore with the
version, date and
time.

Uses data_ok() to calculate a
value from the string.

n/a

)2A

unsigned

8

data_ok_cal

Checks calibrations.
In demo code, it
also checks adjust-
ments.

Checked by data_ok() of calibra-
tion value.

n/a

)2B

unsigned

16

Reserved

)2C.

)2F

Advertising