MIDI Solutions R8 8-output MIDI-controlled Relay Array User Manual

Page 8

Advertising
background image

SYSTEM EXCLUSIVE

To program the R8 to CLOSE upon receiving a System Exclusive message, send it the following programming
commands:

followed by

(

is optional)

where

is the System Exclusive message the relay is being programmed to respond to

All bytes must be in Hexadecimal format (see hexadecimal conversion table at end)

= Relay (00 for Relay1 ... 07 for Relay8)

= Pulse width (CLOSED pulse) in 8 ms increments, or 1 s increments if preceded by 00.

To program the R8 to OPEN upon receiving a System Exclusive message, send it the following programming
commands:

followed by

(

is optional)

where

is the System Exclusive message the relay is being programmed to respond to

All bytes must be in Hexadecimal format (see hexadecimal conversion table at end)

= Relay (00 for Relay1 ... 07 for Relay8)

= Pulse width (OPEN pulse) in 8 ms increments, or 1 s increments if preceded by 00.

To program the R8 to CLOSE Relay8 when the MIDI Machine Control

command (F0 7F 7F 06 02 F7) is

received, and OPEN it when the

command (F0 7F 7F 06 01 F7) is received, send it the following programming

commands:

F0 00 00 50 26 04

F7 followed by

F0 00 00 50 26 04

F7 followed by

F0 00 00 50 26 04 rr 01 (pp) F7

F0 ... F7

pp

F0 ... F7

(max. 20 byes)

rr

pp

F0 00 00 50 26 04 rr 00 (pp) F7

F0 ... F7

pp

F0 ... F7

(max. 20 byes)

rr

pp

Example

07 01

F0 7F 7F 06 02 F7

07 00

F0 7F 7F 06 01 F7

Play

Stop

8

Advertising