Millennia AD-R96 User Manual

Millennia, Media & music, Systems

Advertising
background image

Millennia

Media & Music

Systems 

AD-R96 User Guide

revised 111408


Protecting Against Electrostatic Discharge
Static electricity can harm delicate components on
the AD-R96 board. To prevent static damage,
discharge static electricity from your body before you
touch any electronic components. You can do so by
touching an unpainted metal surface on the HV-3R’s
chassis.

Unplug the HV-3R’s AC power cord before
inserting or removing the AD-R96 board

Clocks - the AD-R96 should have only one clock
source. If running with the internal clock, make sure
SW4 is in the INT position and no external clock is
connected.

Sync
Signals on the BNC connectors should
conform to the AES-3id specification. AES-3,
through an XLR-to-BNC transformer (Neutrik
NADITBNC-F or equivalent) will work fine.
S/PDIF works, but is not specified.


Sample Rate kHz

SW2

SW1

44.1* X1

44

48 X1

48

88.2 X2

44

96 X2

48

Clock Source

SW4

Internal INT
External* EXT


*The arrows point to the
default jumper positions.


Clock Input

J2

Word Clock*

on

AES off


Clock Termination J3
110 ohms*

on

Unterminated off


Clock Output

J4

J5

Word Clock*

2,3

2,3

AES 1,2

1,2

Millennia Media, Inc.

4600 Missouri Flat Road

Placerville, CA 95667

http://www.mil-media.com

(530) 647-0750

Fax (530) 647-9921

 