Milwaukee Tool 2260-21NST User Manual

Page 17

Advertising
background image

M12 160x120 Thermal Imager Operator's Manual

15

230

138.9˚F

95

CANCEL

SAVE

Figure 9. SAVE or CANCEL a New Image

7. To write the image to SD card, press the button

on the arrow keypad or pull the trigger again. Or, to

discard the image, press the arrow button to highlight

CANCEL, then press the button.

NOTE

Every minute, the Thermal Imager pauses to

calibrate its thermal sensor. You will hear clicking

sounds. This is normal behavior. The Thermal

Imager does not respond to button presses during

calibration pauses.

LOW BATTERY

LOW BATTERY

In the live thermal image in Figure 8, the 120.0 °F

reading at the top of the display is the temperature

inside the center target. The bottom of the display

shows the color palette over the temperature span

(in this case, 86 °F to 122 °F). Span is adjusted

automatically in auto-range mode (default setting). This

manual explains how to use manual range settings

under “Optimizing Thermal Images.”

122

120.6˚F

86

MANUAL

AUTO

Figure 8. Live Thermal Image

6. When the display shows the object or scene framed

the way you want it, pull the trigger to take a thermal

picture. The display then presents you with choices to

SAVE or CANCEL the new image. See Figure 9.

Advertising
This manual is related to the following products: