6 appendix b. dmu output quick reference, 1 digital output conversion, Appendix b. dmu output quick reference – Moog Crossbow VG700MB Series User Manual

Page 30: Digital output conversion

Advertising
background image

VG700M User’s Manual

Page 24

Doc.# 7430-0280-01

Rev. F

6 Appendix B. DMU Output Quick Reference

GR is the G-range of the accelerometers. For example, if your DMU has
±4 G accelerometers, GR = 4.

RR is the rate range of the rate sensors. For example, if your DMU has
±200

°/s rate sensors, RR = 200.

6.1

Digital Output Conversion

Data is sent as 16-bit signed integer for all but Temperature. Temperature
sensor data is sent as unsigned integer.

Acceleration

Roll, Pitch, Relative Heading
(Angle Mode)

Accel (G) = data * GR * 1.5/(2

15

-1)

Angle (

°) = data * 180/(2

15

-1)

Rate Temperature

Rate (

°/s) = data * RR * 1.5/(2

15

-1)

Temperature (

°C) =

[(data * 5/4096) – 1.375]*44.44

Advertising