About streams, Installation, Online manual and help – Mutable Instruments Streams User Manual

Page 2: Front panel, Inputs and outputs, Controls

Advertising
background image

About Streams

Streams is a dual-channel toolbox for shaping the am-

plitude and brightness of audio signals or CVs.
Each channel consists of a VCA and a VCF. The control

voltages for these two analog circuits are digitally gen-

erated, by “reacting to,” “following” or “listening to” a

multi-purpose input called EXCITE. There are 4 different

ways in which the module can adjust its gain and cutoff

frequency in response to the excitation signal: envelope

generation, Vactrol emulation, signal following, and

dynamic compression.
Additionally, the VCA gain can be directly controlled by a

CV - independently of the digital control path.

A

B

2

1

3

4

D

C

F

E

digital CV generator

analog VCA

analog VCF

Level mod attenuator

Level

CV in

Signal

input

Excite

input

Shape control and modulation amount

Output

Exp/lin control

Installation

Streams requires a -12V / +12V power supply (2x5 pin

connector). The red stripe of the ribbon cable (-12V side)

must be oriented on the same side as the “Red stripe”

marking on the board. The module draws 30mA from the

-12V rail and 100mA from the +12V rail.

Online manual and help

The full manual can be found online at

mutable-instruments.net/modules/streams/manual

For help and discussions, head to

mutable-instruments.net/forum

Front panel

Inputs and Outputs

1.

Multi-purpose excitation input.

2.

DC-coupled signal input, normalized to a constant

+5V offset.

3.

Unipolar VCA CV input, normalized to a constant +8V

offset. Unity gain is achieved with a voltage equal to +5V.

4.

DC-coupled signal output.

4

1

2

3

Controls

A. B.

Digital CV generator parameters.

SHAPE controls how fast the module adjusts amplitude

and brightness in reaction to the excitation signal. MOD

controls the amount and range of VCF modulation.

These knobs also control compression threshold and

ratio when the dynamic compressor mode is used. More

details are provided in the next pages.

C.

Level CV input attenuator.

D.

Function selector. Cycles through the four functions.

E.

VCA response curve, from exponential to linear.

F.

Metering button. Press to display the bargraph. Press

again to select which signal is to be monitored.

Audio signals are metered with a dB scale of 6dB/LED.

Slow CVs are displayed with a linear scale of 2V/LED -

the LED color indicates signal polarity.

METER

EXCITE

METER

LEVEL

METER

IN

METER

VCA OUT