Back Panel

A – IEC Power socket

B – Wordclock BNC Input

C – Wordclock BNC Output

D – AES/EBU XLR Input

E – S/PDIF Coax Input

F – S/PDIF Optical Input (Toslink)

G – AES/EBU XLR Output

H – S/PDIF Coax Output

Functions

IN – You can select the active input by pressing this button.
The status LED will have a solid glow when there is a valid
incoming signal and it's frequency will be displayed when you
have F-IN selected as the F-DISP. If no signal is present the
LED will be blinking and “no In” will be displayed.
F-DISP – This selects whether the input or output frequency is
shown on the display.
SEL and UP – These buttons allow you to cycle through the
various menu options, frequencies, and make selections.
MODE – This chooses whether you want the SRC to function
synchronously, asynchronously with internal crystal as the
clock source or asynchronously with external wordclock as the
clock source.
OUTPUT WORD LENGTH – This chooses between 24, 20,
and 16 bits as the word length.