6.2 Roll Sensor Mounting Guidelines: Trapeze-Suspended Booms

1. When mounting the roll sensors, mount the roll sensor without the temperature probe on

the trapeze link (boom frame) and the roll sensor with the temperature probe on the

trapeze support (chassis). For optimal performance, minimize the distance from the boom
frame roll sensor to the pivot point (A) and minimize the vertical distance between the
chassis roll sensor and the pivot point (B).

Figure 19: Roll Sensor Mounting on a Trapeze Suspended Boom

2. Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.

3. Both roll sensor cables should be pointing towards the right hand wing of the sprayer.

4. Ensure both roll sensors are mounted adequately and that the cables provide enough slack

to allow sufficient boom roll.