13

4.4

R

OLL

S

ENSOR

I

NSTALLATION

Mount the roll sensors to the included roll
sensor brackets using the machine screws
and nylon lock nuts, as illustrated in Figure
12
.

The roll sensors must be

mounted tightly to the brackets.

Figure 12: Mounting the Roll Sensor

to the Roll Sensor Mounting Bracket


When mounting the roll sensors, use the
following guidelines and refer to Figure 13.

a) The smaller the distance between A and

B in Figure 13, the better the
performance will be.

b) Ensure the roll sensors are sitting

relatively level when the sprayer chassis

and boom are level.

c) Both roll sensors must be mounted with

the circular AMP connector facing
towards the Right-Hand Wing (when
looking from the rear of the sprayer).

Figure 13: General Roll Sensor Mounting Location on a Trapeze Style Boom

Connectors towards
Right-hand Wing 