NORAC UC4+BC+MC2 User Manual
Page 25
Advertising
22
Figure 25: Cable Configurations: C10, C11 and C14
2. Connect the UC4+ power cable (C10)
to the UC4+ control panel in the
sprayer cab. Ensure both plugs (P16
and P4) are connected to the panel
(Figure 25).
Ensure the UC4+ Panel’s power
is OFF for the remaining
installation (Bottom of switch
pressed IN).
3. Connect the 3-pin AMP plug (P3) of
C10 to the 3-pin AMP receptacle (R3)
of C14.
4. Connect the other end of C14 to a
12V, 15 amp source.
5. Route the receptacle end (R16) of C10
out of the cab.
6. Connect the 16-pin AMP plug (P16) of
the valve extension cable (C11) to R16
of C10 (Figure 25).
Figure 26: Cable Configurations: C03, C11 and C12
Advertising