NORAC UC4+BC+SC1 User Manual

Page 13

Advertising
background image

10

proceeding to the largest serial
number on the right hand side
(Figure 10).

5. Sensor cables should run through the

mounting bracket tube and then behind the
member the bracket is mounted onto.
Cable-tie the connector in place. The cable
must not be allowed to hang below the

boom (Figure 6).

Figure 6: Another Acceptable Mounting

Avoid mounting sensors in locations

where they may read from parts of
the boom as shown in Figure 7.

Figure 7: Poor Mounting

(Sensor Reading off Boom)

General mounting rules for UC4+
ultrasonic wing sensors:

a) In its lowest position, the sensor mouth

must be 9 inches or more from the ground.

b) The bottom of the sensor must be at least 9

inches in front of the spray nozzles.

c) The bottom of the sensor must be at least 9

inches above the spray nozzles.

d) Ensure that there are no obstructions within

a 12-inch diameter circle projected directly
below the center of the sensor.

e) The sensor should be approximately vertical

at normal operating heights.

Figure 8: Sensor Mounting Guidelines

A

B

B

D

C

Ultrasonic
Acoustic Cone